Download Print this page
Idem UGB-NET-CS Operating Instructions Manual

Idem UGB-NET-CS Operating Instructions Manual

Safety switches

Advertisement

Quick Links

IDEM Safety Switches
UGB-NET-CS
RFID Guard Interlock with Integrated EtherNet/IP with CIP Safety.
Operating Instructions
Original Instructions - To request this document in other languages please contact
info@idemsafety.com

Advertisement

loading

Summary of Contents for Idem UGB-NET-CS

  • Page 1 IDEM Safety Switches UGB-NET-CS RFID Guard Interlock with Integrated EtherNet/IP with CIP Safety. Operating Instructions Original Instructions - To request this document in other languages please contact info@idemsafety.com...
  • Page 2 Electrical Data ........................12 Mechanical Data ....................... 12 Environmental Data ......................12 Reliability / Safety Data (EN ISO 13849-1) ................. 12 Reliability / Safety Data (EN 62061 / IEC 61508) ............... 12 NOTES ............................. 13 102620 2210 UGB-NET-CS Operating Instructions Contents...
  • Page 3 All relevant safety regulations and standards are to be observed. The UGB-NET-CS complies with the requirements of Cat. 4 / PL e and SIL 3 in accordance with ISO 13849-1, IEC 62061 and IEC 61508. The device implements the following safety functions: •...
  • Page 4 Repair or modification of the UGB-NET is not allowed unless authorised by IDEM and carried out according to operating guidelines. • Safety critical failures which do not lead to the safe state shall be reported to IDEM immediately. • Replace a malfunctioning UGB-NET immediately.
  • Page 5 Operating Instructions IDEM Safety Switches UGB-NET-CS UGB-NET with Rotary Handle Guard Front Guard Rear UGB-NET with Sliding Handle Guard Front Guard Rear 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 6 • Not all connections are required for all applications, the minimum requirement to operate the device is one data connection and one power connection. All 4 ports are utilised when the UGB-NET is used a ‘daisy chain’ configuration. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 7 After the detection of a safety critical error, the UGB-NET shall not be kept in fail- safe state for more than 1 hour. INFORMATION • The device EDS file can be found via the UGB-NET product page of the IDEM website www.idemsafety.com/products or alternatively please contact technical@idemsafety.com 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 8 2. Using a PC station that is configured on the same network as the UGB-NET, run the BOOTP/DHCP tool. 3. Using the MAC address to identify the UGB-NET, select the UGB-NET in the ‘Discovery History’ window and click ‘Add Relation’. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 9 8. Cycle power to the UGB-NET or press and hold the reset button until the LEDs turn red then release to reset the device. The UGB-NET will restart with the configured IP address and with DHCP disabled. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 10 Open or create a project with the PLC CPU, Partner and Ethernet/IP modules added. Right click the Ethernet module and select ‘New Module…’ Find and select the UGB-NET-CIP (will only appear if EDS file imported correctly), click ‘Create’. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 11 Change the Safety Network Number (SNN) to match that of the controller/PLC. On the ‘Safety’ tab, uncheck the ‘Configuration Signature’ box, press OK. The UGB-NET can now be utilised in the PLC program according to the UGB-NET data mapping. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 12 Once the device has been installed and setup within the EtherNet IP / CIP Safety application control software the following checks are necessary to ensure correct operation of the system. • Expected operation of all control circuits. 7. Data Map See technical datasheet supplied with product. For assistance please contact: technical@idemsafety.com 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 13 Diagnostic LED’s are not reliable indicators and cannot be guaranteed to provide accurate information. They should only be used for general diagnostics during commissioning or troubleshooting. Do not attempt to use LEDs as operational indicators. 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 14 Reliability / Safety Data (EN ISO 13849-1) Category Performance Level MTTFd High Reliability / Safety Data (EN 62061 / IEC 61508) Mission Time 20 years SIL CL SIL 3 PFHd (Guard Interlocking / Lock Monitoring) 7.3E-10 PFHd (Emergency Stop Function) 2.3E-9 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 15 Operating Instructions IDEM Safety Switches UGB-NET-CS NOTES 102620 2210 UGB-NET-CS Operating Instructions...
  • Page 16 EC / EU Declaration of Conformity MANUFACTURER: EU REPRESENTITIVE: ADDRESSES: IDEM SAFETY SWITCHES LIMITED IDEM SAFETY SWITCHES Ro SRL Hindley Industrial Estate Hindley Green Bloc OD6, nr. 35 Wigan Bulevardul Timișoara Lancashire București WN2 4HR 061344 United Kingdom Romania DEVICE(s):...