10. Compressor
■ Installation
(1)
Remove the rubber stopper and tube cap (brazed) from the new compressor.
(2)
Install the crankcase heater onto the new compressor.
(3)
Place the 2 pieces of cushioning rubber in the designated positions on the compressor.
(4)
Place the 2 pieces of cushioning rubber onto the legs of the new compressor.
CAUTION
(5)
Place the remaining cushioning rubber onto the new compressor, at the position shown in the figure below.
(6)
Remove the bolts that are temporarily fastening the pieces of cushioning rubber (inner 2 legs), and anchor
the 3 compressor legs using the bolts, washers, and rubber washers.
(7)
Remove the flare nut from the new compressor, and connect the tube-with-flare-nut.
(8)
Shape the tubes and insert them at the 2 welding locations.
2
(9)
Connect a manifold gauge to the high- and low-pressure outlet ports at the outdoor unit where the
compressor was replaced. Connect the manifold gauge to a nitrogen cylinder and perform nitrogen gas
replacement.
(10) Perform copper brazing at the 2 welding locations.
(11) Follow the instructions in "6. Checking for Leakage After Repair" and check for leaks at the outdoor unit where
the compressor was replaced.
CAUTION
(12) Re-install all components that were removed. Re-install the electrical component box in the same position as
it was before.
CAUTION
(13) Follow the instructions in "7. Evacuating System" and apply vacuum to the outdoor unit where the compressor
was replaced.
Cushioning rubber
(Temporary fastening
bolts-2 inner legs)
When setting the compressor into the unit, be careful not to cause any abnormal
deformation of the tube-with-flare-nut.
At this time, also check for leaks at the flare nut connection on the tube-with-flare-nut.
Be sure to check for looseness of the power terminal connections at the compressor
terminal plate, and to check by pulling vertically on the connections. If the terminals
become disconnected easily, replace the wiring Assy.
Tube-with-flare-nut
Front view
Crankcase
heater
Fig. 21
Front view
Cushioning rubber (Inner 1 leg)
Fig. 22
2 - 30
3-WAY ECO-i SYSTEM
Outdoor Unit Repair Procedures
Brazed
locations (2)
Bolt
Washer (1)
Rubber washer (1)

Advertisement

loading