Electrical Connection

Electrical Connection
If your appliance is supplied with a 13 amp. fused plug it can
be plugged into a 13 amp socket for immediate use. Before
using the appliance please read the instruction below.
WARNING: THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE CARRIED
OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA approved fuse
to BS 1362 should always be used, and the fuse cover re-
fitted. If the fuse cover is lost, the plug must not be used until
a replacement is obtained.
Replacemente fuse covers:
If a replacement fuse cover is fitted, it must be of the correct
colours as indicated by the coloured marking or the colour that
is embossed in words on the base of the plug. Replacements
can be obtained directly from your nearest Service Depot.
Removing the plug:
Ifyour appliance has a non-rewireable moulded plug and you
should wish to remove it to re-route the mains cable through
partitions, units etc., please esure that either:
- the plug is replaced by a fused 13 amp re-wireable plug
bearing the BSI mark of approval
- or:
- the mains cable is wired directly into a 13 amp cable
outlet,
controlled by a switch, (in compliance with
BS 5733) which
is accessible without moving the
appliance.
Disposing of the plug:
Ensure that before disposing of the plug itself, you make the
pins unusable so that it cannot be accidentally inserted into
a socket.
Instruction for connecting cable to an altenative
plug:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
- Earth
Blue
- Neutral
Brown
- Live
CAUTION:
- Once the appliance has been installed, the electrical plug
and socket should remain accessible.
- The Company shall not be held responsible for any in-
cidents that occur if these regulations are not observed.
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the terminal
in your plug, proceed as follows:
connect Green & Yellow wire to terminal market "E" or
coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L" or coloured Red.
Connect Blue wire to terminal marked "N" or coloured Black.
If a 13 amp plug (BS 1363) is used it must be fitted with a
13 amp fuse. A15 amp plug must be protected by a 15 amp
fuse, either in the plug or adaptor or at the distribution board.
If you are in any doubt about the electrical supply to your
machine, consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in accordance with
the following code:
BLUE
"NEUTRAL" ("N")
BROWN
"LIVE" ("L")
GREEN AND YELLOW
"EARTH" ("E") or
Disposing of the appliance:
When disposing of the appliance please remove the plug by
cutting the mains cable as close as possible to the plug body
and dispose of it as described above.