Triplett TMP230 User Manual

Triplett TMP230 User Manual

Deep-frying oil tester/oil quality meter

Advertisement

Quick Links

User Manual
TMP230
Deep-Frying Oil Tester/Oil Quality Meter
1.888.610.7664
www.calcert.com
15
10
20
5
25
0
30
sales@calcert.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMP230 and is the answer not in the manual?

Questions and answers

Summary of Contents for Triplett TMP230

  • Page 1 User Manual TMP230 Deep-Frying Oil Tester/Oil Quality Meter 1.888.610.7664 www.calcert.com sales@calcert.com...
  • Page 2 Introduction Congratulations on your purchase of the Triplett TMP230 Deep-Frying Oil Tester. This instrument checks temperature and TPM (Total Polar Materials) in industrial and domestic fryers to know exactly when the oil has to be replaced. Description METER DESCRIPTION 1.888.610.7664 www.calcert.com...
  • Page 3 Safety Please read this manual carefully and completely before you use the device for the first time. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty. The device must only be used as described in this instruction manual.
  • Page 4 The measurement range as stated in the specifications must not be exceeded under any circumstances. Non-observance of the safety notes can cause damage to the device and injuries to the user. Triplett does not assume liability for printing errors or any other mistakes in this manual. Operation Measurement 1.
  • Page 5 Important notes to achieve the most accurate results During the measurement, there should not be any fried food in the oil/fat. After taking out the fried items, wait at least 5 minutes before making a measurement. If you would like to measure in an induction cooker, switch it off as its electromagnetic field can falsify the result.
  • Page 6 Switch on / off alarm LED 1. Use the arrow keys to turn on / off the LEDs. 2. Press the HOLD key to confirm. Switch on / off calibration mode (CAL) Press the arrow keys to switch on / off calibration mode. Press the HOLD key to confirm.
  • Page 7 4. When the displayed value matches the reference value, press the HOLD key to save the value. You can reset your calibration to factory settings by opening the menu item factory settings (RST) via the configuration mode as described under Settings and then pressing the arrow right key and the HOLD key. Switch on / off calibration mode (CAL) Press the arrow keys to switch on / off calibration mode.
  • Page 8 Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase.