Advertisement

Owner's Manual
Original Instructions
Wired Remote Controller XK19
Compatible Models:
BMKH12MCC
BMKH18MCC
BMKH09MFCC
BMKH12MFCC
BMKH18MFCC
BMKH24MFCC
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact the local
agent at 800-865-5931 or visit www.alpinehomeair.com.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BMKH12MCC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Blueridge BMKH12MCC

  • Page 1 Owner's Manual Original Instructions Wired Remote Controller XK19 Compatible Models: BMKH12MCC BMKH18MCC BMKH09MFCC BMKH12MFCC BMKH18MFCC BMKH24MFCC Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local...
  • Page 2 User Notice Never install the wired remote controller in the moist circumstance or expose it directly under ◆ the sunlight. Never beat, throw, and frequently disassemble the wired remote controller and the wireless ◆ remote controller. ◆ Never operate the wired remote controller and the wireless remote controller with wet hands. Do not remove or install the wired controller by yourself.
  • Page 3: Table Of Contents

    Contents Ⅰ Wired Remote Controller XK19 ..............1 Symbols on LCD ..................1.1 Outside View of the Wired Remote Controller ............ 1.2 LCD of the Wired Remote Controller ..............2 Buttons ......................2.1 Buttons on the Wired Remote Controller ............2.2 Function of the Buttons ..................
  • Page 4: Ⅰ Wired Remote Controller Xk19

    Wired Remote Controller XK19 Ⅰ Wired Remote Controller XK19 1 Symbols on LCD 1.1 Outside View of the Wired Remote Controller Mode Enter/Cancel Function Timer On/Off Fig.1 Outside View of the Wired Remote Controller 1.2 LCD of the Wired Remote Controller 4 5 6 7 8 9 101112 13 14 15 16 17 18 19 Fig.2 LCD of the Wired Remote Controller...
  • Page 5: Buttons

    l l o Table 1 Symbols Description Swing function. Sleep function. Running modes of the indoor unit (Cooling, Dry, Fan and Heating). Defrosting function for the outdoor unit. Gate-control function Lock function. High, middle, low or auto fan speed of the indoor unit. Shield functions (buttons, temperature, On/Off or Mode is shielded by the remote monitor.
  • Page 6: Function Of The Buttons

    Wired Remote Controller XK19 2.2 Function of the Buttons Table 2 Name Function Enter/Cancel Function selection and cancellation. ▲ ① Running temperature setting of the indoor unit, range:16~30℃(61~86°F). Timer setting, range:0.5-24 hr. ② ▼ Setting of the high/middle/low/auto fan speed. Mode Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
  • Page 7: Operation Instructions

    Wired Remote Controller XK19 3 Operation Instructions 3.1 On/Off Press On/Off to turn on the unit and turn it off by another press. Note: The state shown in Fig.4 indicates the “Off” state of the unit after power on. The state shown in Fig.5 indicates the “On”...
  • Page 8: Fan Setting

    Wired Remote Controller XK19 Fig.6 3.4 Fan Setting Under the “On”/”Off” state of the unit, press Fan and then fan speed of the indoor unit will change circularly as shown in Fig.7. Middle High AUTO Enter/Cancel Mode Function Timer On/Off Fig.7 3.5 Timer Setting Under the “On”/”Off”...
  • Page 9 l l o Fig. 8 Timer off Setting under the “On” State of the Unit Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s.
  • Page 10: Swing Setting

    Wired Remote Controller XK19 3.6 Swing Setting Swing On: Press Function under on state of the unit to activate the swing function. In this case, Swing Off: When the Swing function is on, press Function to enter the Swing setting interface, with blinking.
  • Page 11: Fresh Air Valve Function Setting

    l l o 3.7 Fresh Air Function Setting Valve Turn on fresh air valve function: Under unit on status, press Function button on the panel to select “Fresh air valve” function option. When icon flashes, it enters fresh air valve setting mode. Previous temperature display position will display the level of fresh air valve.
  • Page 12: Sleep Setting

    Wired Remote Controller XK19 3.8 Sleep Setting Sleep on: Press Function under on state of the unit till the unit enters the Sleep setting Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting interface. After that, press Enter/Cancel to can this function. In the Cooling or Dry mode, the temperature will increase by 1℃...
  • Page 13: Turbo Setting

    l l o 3.9 Turbo Setting Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the room temperature can quickly approach the setting value. In the Cooling or Heating mode, press Function till the unit enters the Turbo setting interface When the Turbo function is activated, press Function to enter the Turbo setting interface and then press Enter/Cancel to cancel this function.
  • Page 14: Energy Saving Function Setting

    Wired Remote Controller XK19 3.10 Energy Saving Function Setting Turn on energy saving function: 1)Energy Saving Setting for Cooling When the unit runs under the COOL or DRY mode, press Function button to select "SAVE" function option, with "SAVE" flashing, and then press ▲ or ▼ to adjust the lower limit, after that, press the Enter/Cancel button to activate this function.
  • Page 15: E-Heater Setting

    l l o 3.11 E-heater Setting E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be Once the wired remote controller or the remote controller enters the Heating mode, this function will be turned on automatically. Press Function in the Heating mode to enter the E-heater setting interface and then press Enter/Cancel to cancel this function.
  • Page 16: Blow Setting

    Wired Remote Controller XK19 3.12 Blow Setting Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press Enter/Cancel to active this function.
  • Page 17: Quiet Function Setting

    Wired Remote Controller XK19 3.13 Quiet Function Setting Turn on quiet function: Under unit on status, press Function button on the panel to select “Quiet” function option. When “Quiet” or “Auto quiet” flashes, it enters quiet function setting mode. Press ▲ or ▼ button to switch between “Quiet”...
  • Page 18: Other Functions

    Wired Remote Controller XK19 3.14 Other Functions (1). Lock Upon startup of the unit without malfunction or under the “Off” state of the unit, press ▲ and ▼ at the same time for 5s till the wired remote controller enters the Lock function. In this case, LCD displays .
  • Page 19 l l o go to the commissioning status, and then adjust the display in the temperature display area to 01 through the button “Mode” and adjust the setting of the fan speed, which comes to two options. 01: Three low fan speeds; 02: Three high fan speeds Pressing the button “On/Off”...
  • Page 20: Installation And Dismantlement

    Wired Remote Controller XK19 4 Installation and Dismantlement 4.1 Connection of the Signal Line of the Wired Remote Controller ● Open the cover of the electric control box of the indoor unit. ● Let the single line of the wired remote controller through the rubber ring. ●...
  • Page 21 Wired Remote Controller XK19 Note:CN1 is 485 communication interface and it used for connecting the 4-core communication wire. These two needle stands(CN2、CN3) are used for connecting the smart zone controller. There is no sequence for these two needle stands. You can connect one or two needle stand(s) basing on the requirement.
  • Page 22 Wired Remote Controller XK19 Smart zone controller Fig.19 Fig.19 shows the schematic diagram of control system connection. XK19 can connect the smart zone controller (integrated control system). “n” indicates the number of communication node address (programmable wired controller XK19). The complete system is composed of the smart zone controller, wired controller XK19 and communication cable.
  • Page 23: Dismantlement Of The Wired Remote Controller

    l l o cord and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm, otherwise the communication of the unit will probably work abnormally. If the air conditioning unit is installed where is vulnerable to electromagnetic interference, ②...
  • Page 24 Wired Remote Controller XK19 Table 4 Meaning of Each Error Error Error Error Error Code Code Return air temperature sensor open/short Drive board communication error circuited evaporator temperature sensor open/short Compressor overheating protection circuited Indoor unit liquid valve temperature sensor Indoor and outdoor units unmatched open/short circuited Indoor gas valve temperature sensor open/...
  • Page 25 Wired Remote Controller XK19 Error Error Error Error Code Code Compressor inhalation temperature sensor error Indoor fan tripping error Communication error between IDU and IDU network address error grid connection Communication error between ODU and Ip address allocation overflow grid connection Main error at grid connection side...
  • Page 26 66174339...