Sony Glasstron Lite PLM-A35E Service Manual page 12

Hide thumbs Also See for Glasstron Lite PLM-A35E:
Table of Contents

Advertisement

[Preparation for Adjustment]
1. Service Jigs
(1) Adjusting remote commander (RM-95-modified)
Note: J-6082-053-B
(2) Extension cable (for remote commander plug converter)
J-6082-291-A
Note: The page will not be changed over, unless the microprocessor in
the adjusting remote commander is a new one (uPD7503-G-C56-
12). In such a case, replace with new microprocessor (8-759-148-
35).
2. Adjusting Remote Commander
For the adjustment, the adjustment data saved in the nonvola-
tile memory (EEPROM) must be rewritten, and for this pur-
pose the adjusting remote commander is used.
The adjusting remote commander makes two-way communi-
cation with the set using a remote control signal line (LANC).
The adjusting remote commander transmits pages, addresses,
and data up/down commands to the set. The set transmits pages,
addresses, and data to the adjusting remote commander.
3. How to Use The Adjusting Remote Commander
(1) Connect the adjusting remote commander to the CN305 on
YM-A01 board via extension cable (J-6082-291-A).
(
At this time, set the switch of extension cable to OFF
(OPEN) position
Turn ON the power on the set.
(2) Set the HOLD switch on the adjusting remote commander to
the HOLD (SERVICE) position.
If connection is normal, the LCD display on the adjusting
remote commander will be as shown in Fig.3-3.
Page
Fig. 3-3
(3) Operate the adjusting remote commander as follows:
• Page change
Press the EDIT SEARCH + button to increase the page.
Press the EDIT SEARCH – button to decrease the page.
There are 16 pages from 0 to F.
Hexadecimal numbers
0 1 2 3 4 5 6 7 8 9 A B C D E F
LCD display
0
1
2 3 4 5 6 7 8 9 A b c d E F
Decimal conversion
0
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15
• Address change
Press the FF (M) button to increase the address.
Press the REW (m) button to decrease the address.
There are 256 addresses from 00 to FF.
• Data change (data setting)
Press the PLAY (N) button to increase the data.
Press the STOP (x) button to decrease the data.
There are 256 data from 00 to FF.
Confidential
PLM-A35E (AEP)
Data
Address
• Adjustment data writing
The PAUSE button must be pressed to write adjustment
data (D page) to the nonvolatile memory (EEPROM). (Un-
less the PAUSE is pressed, new data are not saved in the
nonvolatile memory.)
(4) Select page: 1, address: 00, and set 01 data. Thus, the data
input to page: D is enabled.
(5) After the adjustment finished, select page: 1, address: 00,
and set 00 data. Thus, the data change on page: D is dis-
abled.
(6) After all adjustments finished, turn OFF the main power sup-
ply (9 V) once.
4. Precaution on Use of The Adjusting Remote Commander
Misoperation of the adjusting remote commander could erase
correct data. To prevent this, it is recommended to make a note
of data from page: D before adjustment, and also to make a
note of new adjustment data each time the adjustment of one
item is finished.
Adjusting Remote Commander RM-95 (J-6082-053-B)
)
WIDE
ZOOM
TELE
REC
REVIEW
Page change
EDIT SEARCH
COUNTER
RESET DISPLAY FRAME SLOW
Data change
REC
REW
3-2
NORMAL(NOR)/SERVICE (ADJ)
mode selection
HOLD
START/
STOP
FOCUS
POWER
AUTO/MAN
Data writing
PAUSE
FF
PB
RM-95
STOP
Fig. 3-4
Address
change

Advertisement

Table of Contents
loading

Table of Contents