Technical Specifications - Unicum AN1244 User And Installation Manual

Control box
Table of Contents

Advertisement

This control box is compatible with following motors:
AN1244: PL3210, PL1218, DL3010 and DL1318
AN1274: PL6010, PL3218, PL7710, DL6010, DL7710 and DL3018
« Pulse mode » or « Hold mode » can be selected independently on both directions (open/close).
Overload detection in case of motor slow down during cover operation
Security Loop (for emergency stop or alarms coming from sensors)
Auxiliary Relay (for electrolyser or pump management)
One-digit display for alarm notification and troubleshooting.
CHARACTERISTICS
Power feed tension
Frequency
Monophasic AC Network
Maximum power
Zero load tension
Maximum load current
Dimension (HxLxP)
Weight
Waterproof class
Operation temperature range
Admissible humidity
FUSES CARACHTERISTICS:
AN1244
F1 = Fuse ATO 10A
F2 = Fuse 5x20 3.15A Time lag
AN1274
F1 = Fuse ATO 15A
F2 = Fuse 5x20 4A Time lag
Réf : 004057-02

Technical specifications

AN1244
230
50
L/N/PE
210
30
10
291x241x87 291x241x88
3,5
IP50
0 to 50
0 to 85
User and installation manual
AND1274
230
50
L/N/PE
360
30
15
4,7
IP50
de 0 to 50
de 0 to 85
Unit
V AC
Hz
VA
V DC
A
mm
kg
°C
%
Page : 3/17