NSTALLATION INSTRUCTIONS
Step 5 :
INSTALLATION OF DRAIN HOSE
1 If the end of drain hose does not fit to
the drain line, use a rubber
connector(not supplied) that is
resistant to heat and detergent.
2 This should be available from a
plumbing shop or DIY merchants.
3 There are two typical connections as
shown in Figure A, B.
The S trap spigot must be drilled out cleanly
and free of obstruction to its maximum
internal diameter, if used for drainage.
To prevent siphoning, one of the following
methods must be used:
■ When the drain hose is connected to a
sink S trap or waste disposal unit, the hose
must be looped up to the underside of the
bench top and secured.
Fig. A
All manuals and user guides at all-guides.com
7
■ When the drain hose is connected to a
separate standpipe, it is essential that an
airtight connection be made.
Refer to Fig.B
Fig. B : Drainage connection - stand pipe.
Drain hose Extension
Extend drain hose as shown below.
CAUTION
When you connect or extend drain
hose, make sure that drain hose is not
kinked.
(Bends should have a 40 mm radius.)