MACH SYSTEMS MACH-ETH User Manual page 13

Table of Contents

Advertisement

Short the boot pads together (a pair of tweezers can be used)
Connect the power supply - either USB or external
The device will enter the system bootloader
Release the boot pads
Firmware can be flashed as described in 5.6
Close the enclosure
The steps for Ethernet bootloader:
Disconnect the USB and the external power supply
Open the enclosure
Connect the power supply - either USB or external
Connect the Ethernet cable
Short the eth boot pads together (a pair of tweezers can be used)
The device will enter the Ethernet bootloader
Release the boot pads
Firmware can be flashed as described in 5.4
Close the enclosure
C. With internet browser
Open Chrome internet browser
Type IP address (default IP address is 192.168.1.100) of the device in the
address bar
At the bottom of the page, click on the button Go to USB bootloader to enter
the system bootloader
o Window with the short message is shown
o Firmware can be flashed as described in 5.6
To enter Ethernet bootloader, click on Go to Ethernet bootloader
o Window with short message is shown
o Firmware can be flashed as described in 5.4
D. Send protocol message
MACH SYSTEMS s.r.o.
www.machsystems.cz
info@machsystems.cz
MACH ETH - User Manual
Page 13 of 20

Advertisement

Table of Contents
loading

Related Products for MACH SYSTEMS MACH-ETH

Table of Contents