Fronius Primo GEN24 3.6 Operating Instructions Manual page 180

Hide thumbs Also See for Primo GEN24 3.6:
Table of Contents

Advertisement

DC input data
Max. inverter backfeed current to the
array
PV 1
PV 2
Number of inputs - PV 1
Number of inputs - PV 2
Max. capacity of the module array
against earth
Insulation resistance test limit value
between module array and earth (on
delivery)
Adjustable range of insulation resist-
ance test between module array and
earth
Limit value and tripping time of the
sudden residual current monitoring
(on delivery)
Limit value and tripping time of the
continuous residual current monitor-
ing (on delivery)
Adjustable range of continuous resid-
ual current monitoring
Cyclic repetition of the insulation res-
istance test (on delivery)
Adjustable range for the cyclic repeti-
tion of the insulation resistance test
DC input data battery
Max. voltage
Min. voltage
Max. current
Max. output
DC inputs
AC input/output data
Nominal output power (P
Max. output power
Rated apparent power
Nominal mains voltage
Min. grid voltage
Max. grid voltage
Max. output current
Current (inrush)
Nominal frequency
180
3)
10)
9)
9)
nom
6)
)
1 ~ NPE 220V / 230V / 240 V
36 A
19 A
2
2
1 000 nF
100 kΩ
10 - 10 000 kΩ
30 / 300 mA / ms
60 / 150 mA / ms
90 / 40 mA / ms
300 / 300 mA / ms
30 - 300 mA
24 h
-
455 V
150 V
22 A
5 000 W
1
5 000 W
5 000 W
5 000 W
1)
155 V
1)
270 V
27.5 A
20 A / 1.3 ms
1)
50 / 60 Hz