SuperWorkstation 5039D-I User's Manual
LAN1/2 Enable/Disable
Change the setting of jumper JPL1 and JPL2 to enable or disable the LAN1 and LAN2
Ethernets ports, respectively. The default setting is Enabled.
LAN1/2 Enable/Disable
Jumper Settings
Jumper Setting
Pins 1-2
Pins 2-3
Watch Dog
JWD controls the Watch Dog function. Watch Dog is a monitor that can reboot the system
when a software application hangs. Jumping pins 1-2 will cause Watch Dog to reset the system
if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the
application that hangs. Watch Dog must also be enabled in BIOS. The default setting is Reset.
Note: When Watch Dog is enabled, the user needs to write their own application software
to disable it.
Watch Dog
Jumper Settings
Jumper Setting
Pins 1-2
Pins 2-3
Open
Manufacturer Mode Select
Close pins 2 and 3 of jumper JPME2 to bypass SPI flash security and force the system to
operate in the manufacturer mode, which will allow the user to flash the system firmware from
a host server for system setting modifications. The default setting is Normal.
Manufacturer Mode
Jumper Settings
Jumper Setting
Definition
Pins 1-2
Normal
Pins 2-3
Manufacturer Mode
Definition
Enabled
Disabled
Definition
Reset
NMI
Disabled
45
BIOS Recovery
Use jumper JBR1 to recover the BIOS settings on the motherboard. The default setting is
Normal.
BIOS Recovery
Jumper Settings
Jumper Setting
Definition
Pins 1-2
Normal
Pins 2-3
BIOS Recovery
SMBus to PCI Slots Enable/Disable
Use jumpers JI
2
C1 and JI
2
C2 to connect the System Management Bus (I
Express slots to improve PCI performance. These two jumpers should be set to the same
setting. The default setting is Enabled.
I
2
C for PCI-E Slots
Jumper Settings
Jumper Setting
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
BMC Enable/Disable
Jumper JPB1 allows you to enable the embedded ASpeed AST2400 Baseboard Management
Controller (BMC) to provide IPMI 2.0/KVM support on the motherboard. The default setting
is Enabled.
BMC Enable
Jumper Settings
Jumper Setting
Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
46
Chapter 4: Motherboard Connections
2
C) to the PCI-