Daikin EPRA16DAV3 Installer's Reference Manual page 115

Hide thumbs Also See for EPRA16DAV3:
Table of Contents

Advertisement

EPRA14~18DAV3+W1 + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT W
4P587501-1B – 2020.10
A
B
C
B
3 Fix the cable with cable ties to the cable tie mountings.
NOTICE
Make sure to select and install the safety thermostat according to the applicable
legislation.
In any case, to prevent unnecessary tripping of the safety thermostat, we
recommend the following:
The safety thermostat is automatically resettable.
The safety thermostat has a maximum temperature variation rate of 2°C/min.
There is a minimum distance of 2  m between the safety thermostat and the
motorized 3‑way valve delivered with the domestic hot water tank.
INFORMATION
ALWAYS configure the safety thermostat after its installation. Without configuration,
the indoor unit will ignore the safety thermostat contact.
INFORMATION
The preferential kWh rate power supply contact is connected to the same terminals
(X5M/9+10) as the safety thermostat. Thus, the system can have EITHER preferential
kWh rate power supply OR a safety thermostat.
A
10
9
Q4L
C
8
Electrical installation
|
Installer reference guide
115