6
|
Application guidelines
Underfloor heating or radiators – Wireless room thermostat
Installer reference guide
30
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Highest comfort and efficiency. The smart room thermostat functionality can
decrease or increase the desired leaving water temperature based on the actual
room temperature (modulation). This results in:
-
Stable room temperature matching the desired temperature (higher comfort)
-
Less ON/OFF cycles (more quiet, higher comfort and higher efficiency)
-
Lowest possible leaving water temperature (higher efficiency)
Easy. You can easily set the desired room temperature via the user interface:
-
For your daily needs, you can use preset values and schedules.
-
To deviate from your daily needs, you can temporarily overrule the preset
values and schedules, or use the holiday mode.
Setup
A
Main leaving water temperature zone
B
One single room
a
Receiver for wireless external room thermostat
b
Wireless external room thermostat
The underfloor heating or radiators are directly connected to the indoor unit.
The room temperature is controlled by the wireless external room thermostat
(optional equipment EKRTR1).
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the user interface.
0 (Single zone): Main
B
A
a
b
1 (External room thermostat):
Unit operation is decided by the
external thermostat.
ERGA04~08EAV3(A) + EHBH/X04+08EA/EJ6V+9W
Value
Value
Daikin Altherma 3 R W