OPERATOR'S MANUAL
KEPCO INC.
An ISO 9001 Company.
IMPORTANT NOTES:
1)
This manual is valid for the following Model and associated serial numbers:
MODEL
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
©2018, KEPCO, INC.
P/N 228-1724 REV 3
KEPCO, INC. ! 131-38 SANFORD AVENUE ! FLUSHING, NY. 11355 U.S.A. ! TEL (718) 461-7000 ! FAX (718) 767-1102
ATE 1/2 RACK
POWER SUPPLY
AUTOMATIC TEST EQUIPMENT
MODEL
250W
ATE 6-25, ATE 15-15, ATE 25-10,
ATE 36-8, ATE 55-5, ATE 75-3,
ATE 100-2.5, ATE 150-1.5, ATE 325-0.8
SERIAL NO.
email: hq@kepcopower.com ! World Wide Web: http://www.kepcopower.com
REV. NO.
KEPCO
THE POWER SUPPLIER™
®

Advertisement

loading

Summary of Contents for KEPCO ATE 6-25

  • Page 1 Data subject to change without notice. KEPCO ® ©2018, KEPCO, INC. P/N 228-1724 REV 3 THE POWER SUPPLIER™ KEPCO, INC. ! 131-38 SANFORD AVENUE ! FLUSHING, NY. 11355 U.S.A. ! TEL (718) 461-7000 ! FAX (718) 767-1102 email: hq@kepcopower.com ! World Wide Web: http://www.kepcopower.com...
  • Page 3 FAST MODE is reduced by a factor of from 1.5 to 2.5. Correspondingly, the response time will be increased by the same factor. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A.  TEL (718) 461-7000  FAX (718) 767-1102 email: hq@kepcopower.com  World Wide Web: http://www.kepcopower.com...
  • Page 4 2. To reduce the rise time delay, see C) above: REDUCING RISE TIME DELAY ..3. To reduce the fall time delay, adjust the current limit to a higher value than maximum application cur- rent to ensure that for the “high” level of the programming signal the unit is not forced to enter current limit mode.
  • Page 5 FIGURE 1. PC 12 PIN FUNCTIONS FOR 1/4 RACK MODELS SHOWING PRE-WIRED LOCAL CONTROL CONNECTIONS (PC 13)
  • Page 6 FIGURE 2. PC 12 PIN FUNCTIONS FOR 1/2, 3/4 AND FULL RACK MODELS SHOWING PRE-WIRED LOCAL CONTROL CONNECTIONS (PC 14)
  • Page 7: Digital Meters

    K) DIGITAL METERS ATE models with the suffix DM indicates that the unit has digital meters in place of the analog meters. (NOTE: analog meters are no longer available.) Voltage meter accuracy is 0.02%; current meter accu- racy is 1.5%. Refer to Figures 3, 4, 5 and 6 for front panel views of the quarter rack, half rack, three-quar- ter rack and full rack DM models.
  • Page 8 VOLTAGE Mode Voltmeter Ammeter CURRENT Mode indicator Monitors output voltage Monitors output current indicator from 0 to E max from 0 to I max Lights in Voltage Mode Lights in Current Mode Crowbar SET LEVEL adjustment (recessed) Adjusts trigger level of crowbar circuit A-C power ON/OFF Crowbar SET LEVEL...
  • Page 9 There are no user or operator serviceable parts within the product enclosure. Refer all servicing to qualified and trained Kepco service technicians. 228-1351 COND/CONFORM 060118...
  • Page 10: Safety Instructions

    SAFETY INSTRUCTIONS 1. Installation, Operation and Service Precautions This product is designed for use in accordance with EN 61010-1 and UL 3101 for Installation Category 2, Pollution Degree 2. Hazardous voltages are present within this product during normal operation. The product should never be operated with the cover removed unless equivalent protection of the operator from accidental contact with hazardous internal voltages is provided: There are no operator serviceable parts or adjustments within the product enclosure.