Download Print this page

Technical Information; Installation Considerations - Hans Grohe AXOR Uno 45448 1 Series Installation/User Instructions/Warranty

Advertisement

English

Technical Information

Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate - 38443xx1, 45448xx1
spout
handshower
Max. flow rate - 38445xx1, 45444xx1
spout
handshower
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.

Installation Considerations

• For best results, Hansgrohe recommends that this
unit be installed by a licensed, professional plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete the
installation.
This trim kit requires rough valve 13444181
(not included). The rough valve must be installed, and
the mounting surface complete and made watertight
before installation of this trim kit.
• 38443xx1, 45448xx1 only: This showerhead
is for use with an automatically compensating valve
rated at 1.3 GPM (4.9 L/min) or less.
• 38445xx1, 45444xx1 only: This showerhead
is for use with an automatically compensating valve
rated at 1.5 GPM (5.7 L/min) or less.
2
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
5.8 GPM (22 L/min)
1.75 GPM (6.6 L/min)
5.8 GPM (22 L/min)
2.0 GPM (7.6 L/min)
• This unit is not anti-scald. If required by local
plumbing code, install this unit in combination with
an approved remote pressure balance valve or
other approved device.
• Protection against backflow is provided by a check
valve and by a self-resetting diverter.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.

Advertisement

loading