(1)
OUTPUT POWER (Watts)
20 - 20k Hz, 0.05% THD, 8 ohms/Ch.
1k Hz, 0.1% THD (EIA), 8 ohms/Ch.
20 - 20k Hz, 0.05% THD, 4 ohms/Ch.
1k Hz, 0.1% THD (EIA), 4 ohms/Ch.
1k Hz, 0.1% THD (EIA), 2 ohms/Ch.
Bridge Mono, 20 - 20k Hz, 0.1% THD, 8 ohms
Bridge Mono, 1k Hz, 0.1% THD, 8 ohms
Bridge Mono, 1k Hz, 1.0% THD, 4 ohms
DISTORTION, SMPTE-IM
FREQUENCY RESPONSE
SIGNAL to NOISE, unweighted, 20 - 20k Hz
VOLTAGE GAIN
INPUT SENSITIVITY, Vrms
for rated power into 8 ohms
OUTPUT CIRCUIT TYPE
INPUT IMPEDANCE
DYNAMIC HEADROOM
DAMPING FACTOR (8 ohms)
AMPLIFIER PROTECTION
COOLING
CONTROLS
LED INDICATORS
CONNECTORS
LOAD PROTECTION
POWER REQUIREMENTS
DIMENSIONS
(1)
WEIGHT
(1) NOTE: Due to special construction to meet EN-6100, CE models may have 5-12% (0.5 dBw) less power and 1.2 lb (0.6 kg) more weight.
PLX 1802
PLX 2502
320
425
330
450
525
675
575
750
900
1250
1100
1400
1200
1500
1800
2500
<0.02%, all models
20 - 20k Hz, ±0.5 dB, all models
-107 dB
-106 dB
31.9 dB
34.0 dB
1.28 (+4.4 dBu)
1.15 (+3.4 dBu)
AB
AB/H
10k ohms unbalanced, 20k ohms balanced
2 dB at 4 ohms
>500
Short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads
Continuously variable speed fan; back-to-front air flow through heat sink array
Front:
AC POWER switch, Gain controls (each channel) 21 detents
Back:
Input Configuration Switch (Stereo, Parallel, Bridge), Clip Limiters (On/Off)
Subwoofer Switch (100 Hz Low Cut/Full Range/100 Hz High Cut, each channel)
LF Switch (33 Hz Low Cut/Full Range, 1 each channel)
POWER (blue), SIGNAL (green x 2), -10 dB (green x 2), CLIP (red x 2), BRDG (amber), PAR (amber)
Input:
1/4-inch TRS and female XLR; 20k ohm balanced, 10k ohm unbalanced
Output: Speakon connectors: Ch 1, 4-wires (Ch 1 + Ch 2); Ch 2, 2-wires (Ch 2 only)
Binding posts
Turn-on/turnoff muting, DC fault blocking, Clip limiting, infrasonic filter (-3 dB at 5 Hz).
Refer to rear panel serial number label. Configured at factory for 100, 120 or 220-240 VAC, 50- 60 Hz.
19.0" (48.3 cm) W, 3.5" (8.9 cm) H, 13.9" (35.3 cm) D (from front mounting rails, including rear support
ears)
21 pounds (9.5 kg) net; 26 pounds (11.8 kg) shipping
U.S. patent no. 5767744 and patents pending
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
PLX 3102
PLX 3602
550
725
600
775
900
1100
1000
1250
1550
1800
1900
2500
2100
2600
3100
3600
-107 dB
-107 dB
35.0 dB
35.9 dB
1.23 (+4.0 dBu)
1.25 (+4.2 dBu)
AB/H
AB/H
EN
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plx-1104Plx-3602Plx seriesPlx 1802Plx 2502Plx 3102

Table of Contents