Dimensional Drawing; Electrostatic Discharge (Esd) Precautions Procedure - Bryant G Series Installation & Operating Instructions Manual

Upflow gas-fired induced-combustion furnaces
Table of Contents

Advertisement

"
1
28
2
FLUE COLLAR
7
-IN. DIA HOLE
8
POWER ENTRY
7
-IN. DIA
8
ACCESSORY
1
3
-IN. DIA HOLE
"
4
7
39
8
GAS ENTRY
1
-IN. DIA HOLE
2
THERMOSTAT
WIRE ENTRY
SIDE INLET
"
5
24
16
"
11
16
AIR INLET
UNIT SIZE
024045
036045
024070
036070
042091
048091
036110
048111
060111
048135
060135
060155
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE
CAUTION: Electrostatic discharge can affect electronic
components. Take precautions during furnace installation
and servicing to protect the furnace electronic control.
Precautions will prevent electrostatic discharges from
personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing
the control to electrostatic discharge by putting the
furnace, the control, and the person at the same electro-
static potential.
"
1
2
16
1"
"
3
5
8
"
5
12
16
"
13
5
16
"
2
3
8
3"
"
11
16
NOTES:
1. Two additional
2. Minimum return-air opening at furnace:
a. For 800 CFM–16-in. round or 14
b. For 1200 CFM–20-in. round or 14
c. For 1600 CFM–22-in. round or 14
d. For airflow requirements above 1800 CFM, use both side inlets,
a combination of 1 side inlet and the bottom, or the bottom only.
Fig. 1—Dimensional Drawing
TABLE 2—DIMENSIONS (IN.)
A
D
14-3/16
12-9/16
14-3/16
12-9/16
14-3/16
12-9/16
14-3/16
12-9/16
17-1/2
15-7/8
21
19-3/8
17-1/2
15-7/8
21
19-3/8
24-1/2
22-7/8
21
19-3/8
24-1/2
22-7/8
24-1/2
22-7/8
A
"
D
13
16
"
3
5
8
11
2
16
"
13
5
16
"
3
2
8
TYP 1 "
"
11
16
E
"
5
8
TYP
7
-in. dia knockouts are located in the top plate.
8
1
x 12-in. rectangle.
2
1
x 19
2
1
x 23
2
E
VENT CONN
12-11/16
12-11/16
12-11/16
12-11/16
16
19-1/2
16
19-1/2
23
19-1/2
23
23
1. Disconnect all power to the furnace. DO NOT TOUCH
THE CONTROL OR ANY WIRE CONNECTED TO THE
CONTROL PRIOR TO DISCHARGING YOUR BODY'S
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the
furnace chassis which is close to the control. Tools held in
a person's hand during grounding will be satisfactorily
discharged.
3. After touching the chassis you may proceed to service the
control or connecting wires as long as you do nothing that
recharges your body with static electricity (for example; DO
NOT move or shuffle your feet, DO NOT touch un-
grounded objects, etc.).
—2—
AIRFLOW
"
1
2
16
19"
OUTLET
1"
7
-IN. DIA
8
POWER ENTRY
"
1
1
-IN. DIA
2
R.H. GAS ENTRY
7
-IN. DIA ACCESSORY
8
1
-IN. DIA THERMOSTAT
2
WIRE ENTRY
SIDE INLET
"
1
23
4
SIDE RETURN
DUCT LOCATION
1
-in. rectangle.
2
1
-in. rectangle.
4
SHIP. WT (LB)
4
4
4
4
4
4
4
4
4
5
5
5
"
13
16
"
1
14
2
"
3
1
4
1"
A88367
122
124
132
134
150
154
160
166
184
178
194
204