Summary of Contents for National Instruments GPIB-100

  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments GPIB-100 at our website:...
  • Page 2 GPIB-100A User Manual March 1990 Edition Part Number 320063-01 © Copyright 1985, 1991 National Instruments Corporation. All Rights Reserved. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 National Instruments Corporation 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 (800) IEEE-488 (toll-free U.S. and Canada) Technical support fax: (512) 794-5678 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4 Any action against National Instrument must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner's failure to follow the National Instruments installation, operation, or maintenance instructions;...
  • Page 5 Be sure that the equipment is plugged into a grounded outlet and that the grounding has not been defeated with a cheater plug. If necessary, consult National Instruments or an experienced radio/television technician for additional suggestions. The following booklet prepared by the FCC may also be helpful: How to Identify and Resolve Radio-TV Interference Problems.
  • Page 6 The following document is a reference that covers in greater detail specific topics introduced in this manual: • ANSI/IEEE Standard 488-1978, IEEE Standard Digital Interface for Programmable Instrumentation. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 Mbytes million bytes millimeter µsec microsecond nsec nanosecond second volts Volts Alternating Current watt GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Table Of Contents

    System Controller Detection.................... 4-2 Active Controller Detection....................4-2 Source Handshake Detection ................... 4-2 Parallel Polling..................... 4-3 Data Direction Control..................4-4 EOI..........................4-4 © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 Cable Assembly Wire List ....................D-1 Appendix E Multiline Interface Messages ..................E-1 Appendix F Mnemonics Key ........................F-1 GPIB-100A User Manual viii © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10 Table 1-5. Environmental Characteristics ................. 1-5 Table 1-6. Physical Characteristics.................... 1-6 Table 1-7. Components and Accessories.................. 1-6 Table D-1. Cable Assembly Wire List..................D-1 © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11: Description Of The Gpib-100A

    Furthermore, regardless of the distance, there is no speed degradation at all for transfers between devices on the same side of the © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12: Figure 1-2. Typical Gpib-100A Extension System (Physical Configuration)

    (System Controller, (Listener) (Talker and Listener) (Listener) Talker, and Listener) Unit Under Test Figure 1-3. Typical GPIB-100A Extension System (Logical Configuration) GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13: Gpib-100A Specifications

    T1 is the data settling time (DIO valid to DAV) and varies according to the type of drivers and the system configuration used. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14: Table 1-2. Performance Characteristics

    Talker/Listener/Controller or Talker/Listener (Talk Only) Parallel Poll Response Buffered Parallel Poll Response or modes Unbuffered Parallel Poll Response GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 15: Table 1-4. Electrical Characteristics

    UL Listed 220V Version UL Listed and also classified by Underwriters Laboratories Inc. in accordance with International Electrotechnical Commission publication 950 © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Table 1-6. Physical Characteristics

    Single Rack-Mount Kit 180304-01 Dual Rack-Mount Kit 180304-02 Note: All part numbers in this table are National Instruments part numbers. GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 17: Chapter 2 Installation

    If the equipment is damaged, do not attempt to operate it before contacting National Instruments for instructions. Retain the shipping material for possible inspection by carrier or reshipment of the equipment.
  • Page 18: Grounding Configuration

    Mounting The GPIB-100A enclosure is designed for table top operation or for rack mounting. Single and dual unit rack mounting kits are available from National Instruments for field installation. Connecting to Hewlett-Packard Controllers To achieve very high data transfer rates and long cable spans between devices, many Hewlett- Packard (HP) controllers and computers, such as the 64000 series, use a preload technique on the unit designated Master Controller.
  • Page 19: Configuration And Operation

    GPIB signals change accordingly. Chapter 4, Theory of Operation, contains a more thorough discussion of this. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Talker/Listener (Tl) Mode

    The GPIB-100A uses either Approach 1 or 2, selected at switch S1, position 3. Set this switch as shown in Figure 3-2. GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21: Buffered Ppr Mode (Approach 1)

    IDY message is sent to the remote bus and the response is returned as fast as propagation delays allow. The Controller must allow time to receive the response. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22: Mixed Mode Operation

    The preferred operating mode is to keep both extenders and at least two-thirds of the devices on both buses powered on when there is any GPIB activity. GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23: Chapter 4 Theory Of Operation

    Register/Capacitor Delay (RCD) network directly or indirectly clears all flip-flops (FFs) to an initialized state. PON remains active until both units in the extension are powered on. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24: System Controller Detection

    The Remote Source (RS) handshake FF U36B is cleared via U33B on the following events: • Before the Active Controller is identified (TLC mode (U33A) only). GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25: Parallel Polling

    BUS PP is received at the local unit through U10C. When the local poll is over (ATN or EOI unasserted), FF U45B is cleared and U36D is set (via U37B/C and U26A). Setting U36D latches © National Instruments Corporation GPIB-100A User Manual...
  • Page 26: Data Direction Control

    GPIB if the local unit is conducting a parallel poll (U27A/B, U37A and transceiver U1A) or if the RS remote response (RR) is set and the local unit is not conducting a poll (U47A). GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 27: Appendix A Operation Of The Gpib

    The GPIB is a bus like a typical computer bus except that the computer has its circuit cards interconnected via a backplane bus whereas the GPIB has standalone devices interconnected via a cable bus. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 28: System Controller And Active Controller

    • 8 data lines • 3 handshake lines • 5 interface management lines GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29: Data Lines

    NRFD indicates when a device is ready or not ready to receive a message byte. The line is driven by all devices when receiving commands and by Listeners when receiving data messages. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Ndac (Not Data Accepted

    The EOI line has two purposes. The Talker uses the EOI line to mark the end of a message string. The Active Controller uses the EOI line to tell devices to identify their responses in a parallel poll. GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 31: Physical And Electrical Characteristics

    See Figures A-2 and A-3. Figure A-2. Linear Configuration of the GPIB Devices © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32: Figure A-3. Star Configuration Of Gpib Devices

    TTL low level (≤ 0.8 V), and when DAV is false, it is a TTL high level (≥ 2.0 V). GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 33: Configuration Restrictions

    National Instruments provides two extenders which allow longer cable spans. These products are the GPIB-100A and the GPIB-110. Both must be used in pairs, one at each end of the extension cable.
  • Page 34: Appendix B Schematic Diagram

    Appendix B Schematic Diagram This appendix contains the schematic diagram for the GPIB-100A. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 36: Gpib-100A Parts Locator Diagram

    This appendix contains the parts locator diagram for the GPIB-100A. The parts locator diagram shows the locations of the GPIB-100A configuration jumpers and switches. Figure C-1. GPIB-100A Parts Locator Diagram © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 37: Cable Assembly Wire List

    Appendix D Cable Assembly Wire List This appendix contains the wire list for the GPIB-100A Transmission Cable. © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 38 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 39 Appendix E Multiline Interface Command Messages The following tables are multiline interface messages (sent and received with ATN TRUE). © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 40: Multiline Interface Messages

    Group Execute Trigger My Talk Address Go To Local Parallel Poll Configure Local Lockout Parallel Poll Disable My Listen Address GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 41 MSA30,PPD Serial Poll Enable Parallel Poll Enable Parallel Poll Unconfigure Take Control Selected Device Clear Unlisten Serial Poll Disable Untalk © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 42: Appendix F Mnemonics Key

    GPIB Not Ready For Data line status Bit Power-On Reset Pulse Parallel Poll (scan all status flags) Parallel Poll Response Remote Active Controller Resistor/Capacitor Delay © National Instruments Corporation GPIB-100A User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 43 Remote Enable Ready for Data Remote Response Remote Source Remote System Controller Service Request Talker Talker/Listener Talker/Listener/Controller (GPIB Adapter) Transistor/Transistor Logic GPIB-100A User Manual © National Instruments Corporation Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 44 User Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: GPIB-100A User Manual Edition Date March 1990 Part Number: 320063-01 Please comment on the completeness, clarity, and organization of the manual.