Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be
installed in a column and the column must be firmly fixed to the wall with commercially available brackets.
IMPORTANT!
All installation or maintenance operations must be performed with the appliance disconnected
from the mains electricity supply.
To guarantee correct ventilation, leave a gap at the bottom of the cabinet
(see measurements below).
M
k
SIDE
n
CABINETRY DIMENSIONS
Minimum inside width of cavity
I
Overall width of cabinetry
J
Minimum inside height of cavity
K
Overall height of cabinetry
L
Minimum inside depth of cavity
M
Ventilation Air Gap
n

CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY)

L
EB24 MODELS
inches (mm)
22 1/16" (560)
23 5/8" (600)
17 3/4" (450)
18 1/8" (460)
21 7/16" (545)
J
I
Electrical supply
TOP
2" (50)
5/8–13/16"
PROUD INSTALL
(16–20mm)
13/16"
(20mm)
5/8–13/16"
FLUSH INSTALL
(16–20mm)
13/16"
(20mm)
min 1/16" (2mm)