Problem: Water leaking from faucet airgap hole.
Cause: Drain side of faucet airgap (3/8" black tub-
ing) plugged, restricted or incorrectly con-
nected to drain point.
Problem: Water leaks at push connect fittings
Cause: Tubing not cut square.
Cause: Tubing not pushed in all the way.
Cause: Tubing nicked.
Cause: Outer tubing surface finish not smooth. Correction:
Questions? Call Toll Free 1-866-972-0135
When you call, please be prepared to provide the model, date code and serial number,
Troubleshooting
Correction:
Inspect and eliminate restriction or plug. Check that drain line is
routed properly. Refer to installation instructions for proper drain
connection. See pages 6 & 10.
Cut tubing square. See pages 14 & 15.
Correction:
Correction:
Push tubing in all the way. See pages 14 & 15.
Remove tube from connection. Remove nicked portion by cutting
Correction:
tube to shorter length. Reinsert in connection. See pages 14 & 15.
If removing the drain line, leave in place the elbow fitting that it con-
nects to. See page 21.
Remove tube from connection. Remove problem area by cutting
tube to shorter length. Reinsert in connection. See pages 14 & 15.
If removing the drain line, leave in place the elbow fitting that it con-
nects to. See page 21.
found on the rating decal, located inside the cover.