SELECT LOCATION OF REVERSE OSMOSIS
FAUCET MOUNTING HOLE
You will need to select the location of the Reverse
Osmosis Faucet. You have three options to choose
from:
• Use the existing sink top hole for the spray hose
or soap dispenser (Must be 1-1/4" in diameter)
• Drill a new hole in the sink
• Drill a new hole in the countertop next to the
sink
1. Determine where you are going to install your
Reverse Osmosis Faucet.
2. Check to ensure the Reverse Osmosis faucet will
mount flat against the mounting surface.
3. Visually review the routing of the tubes from the
Reverse Osmosis filter assembly to the faucet.
Check to ensure there is adequate tube routing
space between the faucet and filter assembly.
4. If drilling is needed, drill a 1-1/4" diameter hole in
the mounting surface.
IMPORTANT: Drilling holes into countertops and
sinks should only be performed by an installer
who is qualified for drilling such materials.
Drilling of surfaces made of stone or solid sur-
face materials such as granite, marble, Corian™
or other plastic resin products or sinks made of
porcelain or stainless steel may cause perma-
nent, irreparable damage to the sink or counter-
top surface.
INSTALL BATTERY
When the coin battery is first applied at initial start up,
the LED indicator light will flash in red, amber, green
sequence. All timers and counters are reset to zero. In
order to reset the time and gallon count feature, push
the button on the PWA and hold until the LED flashes
and release.
The battery needs to be replaced at the time of filter
replacement. Use only lithium batteries (CR 2032 or
equivalent). Use care when inserting the battery to
align it correctly on the PWA with the proper polarity.
Improper placement of battery could damage electron-
ics.
Step E - Install RO Faucet
12
Battery
PWA Board
Reset Button
FIG. 14