Page 1
System tested and certified by NSF International against NSF/ANSI Standards 42 & 58. See performance data sheet for details. Manufactured and warranted by Ecodyne Water Systems LLC Designed, Engineered & 1890 Woodlane Drive Assembled in the U.S.A. Woodbury, MN 55125...
Warranty ONE YEAR LIMITED WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM (Except filter cartridges and R.O. membrane) Warrantor: North Star Water Conditioning, 1890 Woodlane Drive, Woodbury, MN 55125 Warrantor guarantees, to the original owner, that the Reverse Osmosis Drinking Water System, when installed and maintained in accordance with the instructions, will be free from defects in materials and workmanship for a period of one (1) year from the date of purchase.
Unpack and Check Your Carton INSPECT SHIPMENT NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not per- Your Reverse Osmosis Drinking Water System is mit the use of saddle valves. shipped complete in one carton. Remove all items from If you live in the state of Massachusetts, review your shipping carton.
Plan Your Installation PLAN YOUR INSTALLATION TOOLS NEEDED Read through the entire manual before beginning your installation. Follow all steps exactly. Reading this manual will also help you get all the benefits from your system. Your Reverse Osmosis Drinking Water System can be installed under a sink or in a remote location.
Page 7
Plan Your Installation All install parts included in package. Drain Adapter for Reverse Tee Feed Osmosis Adaptor Waste Water Cold Water Supply Reverse COLD Osmosis Assembly Storage Tank Sink Drain P-Trap Shutoff Valve Typical Under Sink Installation FIG. 4 Outside Faucet Outside Faucet (Hard Water) (Hard Water)
Overview and Site Preparation OVERVIEW Read through the entire manual before beginning your installation. There are seven steps to installing your Drinking Water system. They are as follows: STEP A - Install Cold Water Supply fitting STEP B - Install Drain Adapter STEP C - Install Reverse Osmosis Assembly STEP D - Install Storage Tank STEP E - Install Reverse Osmosis Faucet...
Step A - Install Supply Water Fitting Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. Refer to the Specifications page for supply water requirements. The fit- ting must provide a leak-tight connection to the RO 1/4" tub- ing.
Step B - Install RO Drain Under Sink INTRODUCTION Single trap Double Trap A suitable drain point is needed for the drain water from the Reverse Osmosis Filter. You have two options to choose from: Drain • Install the Drain Adapter included with your unit Adapter See Fig 8, Fig.
Page 11
Step B - Install RO Drain In Remote Location Outside Faucet (Hard Water) Outside Faucet BLUE Tubing (Hard Water) to Reverse Osmosis Faucet Soft, Cold Water Soft, Hot GREEN Tubing Soft water Water to Reverse to Reverse Shutoff Osmosis System Osmosis Valve System...
Step C: Install RO Filter Assembly INSTALL REVERSE OSMOSIS FILTER Hanger ASSEMBLY Washer (2) Screw (2) The Reverse Osmosis Filter Assembly is mounted on hanger washers. See Fig 13. The hanger washers allow you to lift the fil- ter assembly from the washers without any hardware removal.
Step D - Install Storage Tank The fitting on the supply tank may need to be tightened 7-8 full turns to get a good seal. Do not overtighten. Tubing Connector INSTALL STORAGE TANK Tank Nipple 1. Apply of thread sealing tape (2 wraps clockwise) to the threads on the nipple at the top of the tank.
Page 14
Step E: Install RO Faucet SELECT LOCATION OF REVERSE OSMOSIS FAUCET MOUNTING HOLE You will need to select the location of the Reverse Osmosis Faucet. You have three options to choose from: • Use the existing sink top hole for the spray hose or soap dispenser (Must be 1-1/4”...
Step E: Install RO Faucet (cont.) INSTALL REVERSE OSMOSIS FAUCET 1. Locate and organize your RO faucet install parts. Refer to Fig. 16. 2. Snap the o-ring into the groove on the bottom of the ring and slide the monitor ring onto the faucet stud. The monitor ring LED wire must be routed through the sink or counter- top hole and through the spacer, if used.
Step F - Connect Tubes HOW TO CUT AND CONNECT THE TUBES Push-in Fitting Your Reverse Osmosis system includes push-in fittings Foam Plug for quick tubing connection. Review the following instructions before connecting the tubes in the next step. Failure to follow these instructions may lead to future leaks.
Page 17
Step F - Connect Tubes (cont.) NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appear- ance, it may be necessary to keep the assembly on the hanger washers for service.
Step G - Sanitize, Test and Purge System SANITIZE THE SYSTEM Sanitizing is recommended immediately after installa- tion of the Reverse Osmosis system. It’s also recom- mended after servicing inner parts. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system.
Page 19
Step G - Sanitize, Test and Purge System (cont.) PRESSURE TEST THE SYSTEM Reverse Osmosis NOTE: Complete the sanitizing procedures on the Kitchen Faucet preceding page before pressure testing. Faucet To pressure test the system, complete the following steps. 1. Open the water supply valve to the Reverse Osmosis system.
How Your RO Water System Works INTRODUCTION: Your Reverse Osmosis (RO) Drinking Water System uses your household water Battery PWA Board pressure to force water through three filters. Minerals and impurities are filtered out. Delicious tasting drink- ing water goes to the storage tank-ready for your use. Minerals and impurities are sent down the drain.
Page 21
How Your RO Water System Works PRODUCT WATER FAUCET Air Gap PRODUCT WATER Gravity Drain DRAIN WATER Drain Flow AUTOMATIC Check Control SHUTOFF Valve WATER GREEN BLUE PRODUCT PREFILTER POSTFITLER WATER STORAGE MEMBRANE YELLOW FIG. 28 Reverse Osmosis Water Flow Schematic Water Flow Description 1.
Maintenance PREFILTER/POSTFILTER MAINTENANCE NOTE: It is recommended to replace the battery, prefilter and postfilter cartridges at least every 6 months of product water use. Replace more often if Cover they begin to plug with sediment. The prefilter and postfilter are replaceable sediment cartridges with activated carbon in their composition.
Page 23
Maintenance FLOW CONTROL The flow control is required for proper operation of the Flow Control Reverse Osmosis system. See Fig. 30. The flow con- Insert trol, located inside the push-in elbow fitting on the drain Push-in port of the system housing, keeps water flowing through Elbow Fitting the membrane at the required rate.
Troubleshooting Problem: Chlorine taste and/or odor in the RO product water. Cause: The level of chlorine in your water supply Correction: If the water supply contains more than 2.0 ppm of chlorine, addition- exceeds maximum limits, and has al filtering of the water supply to the Reverse Osmosis is needed. destroyed the Reverse Osmosis mem- Contact your local water supplier.
Page 25
Troubleshooting Problem: Water leaking from faucet airgap hole. Cause: Drain side of faucet airgap (3/8” black tub- Correction: Inspect and eliminate restriction or plug. Check that drain line is ing) plugged, restricted or incorrectly con- routed properly. Refer to installation instructions for proper drain nected to drain point.
Parts List Part No. Description Part No. Description Automatic Shutoff Kit (incl. Key No. 3, Rep’l Manifold Assembly – 7333145 7296521 4 of Key No. 2 & 6 of Key No. 1) (includes Key Nos. 1-8 & 11-14) Mounting Hardware Kit Screw (6 req’d) –...
Page 28
- PARTS RETURN TAGS - If you have a defective part or assembly under warranty, please fill in a parts return tag. Cut out the tag and include it with the defective part when you return it to the place where you purchased the unit.