Miller Millermatic 210 Owner's Manual page 19

Hide thumbs Also See for Millermatic 210:
Table of Contents

Advertisement

2-11. Positioning Jumper Links
3
1
2-12. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
200 VOLTS
230 VOLTS
S-153 980
2
Circuit Breaker
1
2
, Time-Delay
3
Normal Operating
Check input voltage available at
site and listed on the machine rating
label.
1
Jumper Links Access Door
Open door.
2
Jumper Link Label
Check label – only one is on unit.
3
Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure access door.
Tools Needed:
3/8 in
Ref. 802 476-C
200
230
32
28
35
30
45
40
10
10
89
118
(27)
(36)
10
10
OM-1325 Page 15