Utilization Rules - Hyundai H-DH10-P81WF Instruction Manual

Electric dehumidifier
Table of Contents

Advertisement

Available languages

Available languages

IM2021
Water Full Indication Flashes
Room temperature ˂ 5°C,or ˃
35 °C
Is the air filter clogged?
Bad
functioning
Is the intake duct or discharge
duct obstructed?
No
air
Is the filter clogged?
intake
Is the machine put in the plat
Loud noise
place?
when
running
Is the filter clogged?
E2
Humidity sensor problem
Environmental humidity is below
LO
20%
Environmental
HI
above 90%
Low temperature protection, the
environmental
CL
5℃
High
the environmental temperature
CH
>38℃

15. UTILIZATION RULES

After the lifetime of the device expires, it should be recycled in compliance with the
laws, rules and methods in region of recycling. Detailed information about the recycling
of the device, you can receive from a representative of the local authorities, after
providing full information about the device. The manufacturer and authorized
organization of the manufacturer do not carry responsibility for the fulfillment by the
Buyer of the requirements of legislation on utilization and methods of utilization of the device
selected by the Buyer. The lifetime of the device is indicated in the warranty card. Warranty
period for the device and warranty terms are specified in the warranty card. The warranty card is
an integral part of the documentation supplied with this unit. If there is no warranty card in the
delivery set, ask for it from the Seller. The warranty card provided by the Seller must conform to
the manufacturer's form.
The manufacturer and the authorized organization of the manufacturer remove responsibility for
any possible harm which can be caused to people, animals or property directly or indirectly, if
this harm occurred as a result of noncompliance with the rules and operating conditions,
installation of the device, intentional or reckless actions of the user- and / or third parties, as well
as in situations caused by natural and / or anthropogenic accidents.
humidity
temperature<
temperature
protection,
Drain water tank and reset it, or re-position
the water tank to right place
Self-Protection designed to protect the unit.
Can not work under such temperature
Clean the air filter as instructed
Remove the obstruction from the discharge
duct or intake duct.
Wash the filter
Put the machine on the plat ground
Wash the filter
Change a sensor
is
The
dehumidifier
protection
35
shuts
down
for
self-

Advertisement

Table of Contents
loading

Table of Contents