S+S Regeltechnik THERMASGARD ETF 6-KV Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD ETF 6-KV Operating Instructions, Mounting & Installation

Screw-in/immersion temperature sensor with neck tube, with passive output
Hide thumbs Also See for THERMASGARD ETF 6-KV:
Table of Contents
  • Technical Data
  • Caractéristiques Techniques
  • Montage et Mise en Service
  • Технические Данные
  • Монтаж И Ввод В Эксплуатацию

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-2140-0000-1XX 21400-2021 V111 02 ⁄ 2021
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Einschraub- ⁄ Tauch-Temperaturfühler mit Halsrohr,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Screw-in ⁄ immersion temperature sensor with neck tube,
with passive output
F
Notice d'instruction
Sonde de température à visser ⁄ à immerger avec tube intermédiaire,
avec sortie passiveavec sortie passive
r
Руководство по монтажу и обслуживанию
Ввинчиваемый ⁄ погружной датчик температуры с горловиной,
с пассивным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
ETF 6 xx
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
ETF 6
(IP 54)
ETF 6 - KV
(IP 65)
ETF 6 - Q
(IP 65)
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Advertisement

Table of Contents
loading

Summary of Contents for S+S Regeltechnik THERMASGARD ETF 6-KV

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄...
  • Page 2 D G F r ETF 6 xx THERMASGARD ®  ø70 ~ 80 M20 x1.5 2-Leiteranschluss (Standard) ETF 6 xx Maßzeichnung 2-wire connection (Standard) Dimensional drawing ø70 ~ 80 1x 2 fils (Standard) Plan coté Двухпроводное соединение M20 x1.5 Габаритный чертеж (стандартное...
  • Page 3: Technical Data

    THERMASGARD ® ETF 6 Rev. 2021 - V16 Einschraubwiderstandsthermometer ⁄ Temperaturfühler mit Halsrohr THERMASGARD ® ETF 6 1x Zweileiterschaltung mit passivem Ausgang, mit Anschlusskopf aus Aluminium (optional mit Kabelverschraubung oder (Standard) M12-Steckverbinder nach DIN EN 61076-2-101) und geradem Schutzrohr. Der Kanalfühler dient zur Temperaturerfassung in flüssigen oder gasförmigen Medien. Der Einsatz erfolgt in Rohrleitungen, Behältern oder Speichern, vorzugsweise da, wo Rohre oder Behälter isoliert werden müssen.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden technischen Parameter der Thermometer mit den realen Einsatz- Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. be dingungen zu erfolgen, insbesondere: Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind –...
  • Page 6 THERMASGARD ® ETF 6 Rev. 2021 - V16 Screw-in resistance thermometer ⁄ temperature sensor with neck tube THERMASGARD ® ETF 6 1x two-wire connection with passive output, with connecting head made from aluminium (optionally with cable gland or Standard M12 connector according to DIN EN 61076-2-101) and straight protective tube. The duct sensor is used to detect temperatures in liquid or gaseous media.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical parameters comply with the actual conditions at the place of utilization, only be connected to safety extra-low voltage. Consequential damages in particular in respect of: caused by a fault in this device are excluded from warranty or liability.
  • Page 9: Caractéristiques Techniques

    THERMASGARD ® ETF 6 Rev. 2021 - V16 Thermomètre à résistance à visser/sonde de température avec tube intermédiaire 1 x 2 fils ® THERMASGARD ETF 6 avec sortie passive, tête de raccordement en aluminium (en option Standard presse-étoupe ou connecteur M12 selon DIN EN 61076-2-101) et tube de protection droite. La sonde de mesure pour montage en gaine sert à...
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux conditions d’utilisation Veillez à ne brancher l’appareil que sur un réseau de très basse tension de sécurité.
  • Page 12: Технические Данные

    THERMASGARD ® ETF 6 Rev. 2021 - V16 Ввинчиваемый термометр сопротивления / датчик температуры с горловиной THERMASGARD ® 1 Двухпроводное подключение ETF 6 с пассивным выходом, с присоединительной головкой из алюминия (опционально с стандартное исполнение резьбовым кабельным вводом или разъемом M12 согласно DIN EN 61076-2-101) и прямой защитной...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14: Монтаж И Ввод В Эксплуатацию

    Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, должно осуществляться исключительно к безопасно малому напряжению. в особенности: Повреждения приборов вследствие несоблюдения упомянутых требований –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры Pt 100 Pt 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (KP10) 1.8 kOhm 10 kOhm 20 kOhm °...

Table of Contents