Download Print this page
S+S Regeltechnik Thermasgard ETF7 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik Thermasgard ETF7 Series Operating Instructions, Mounting & Installation

Screw-in/immersion temperature sensors with neck tube (stepped once) with passive output

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6002-1500-2011-000 21500-2016 V100 11 ⁄ 2015
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Einschraub- ⁄ Tauch-Temperaturfühler
mit Halsrohr (einfach abgesetzt),
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Screw-in ⁄ immersion temperature sensors
with neck tube (stepped once)
with passive output
F
Notice d'instruction
Sonde de température à visser ⁄ à immerger
avec tube intermédiaire (à épaulement simple),
avec sortie passive
r
Руководство по монтажу и обслуживанию
Ввинчиваемый ⁄ погружной датчик температуры
с горловиной (с одноступенчатым сужением),
с пассивным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ETF 7
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.

Advertisement

loading

Summary of Contents for S+S Regeltechnik Thermasgard ETF7 Series

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r ETF 7 THERMASGARD ®  ETF 7 Maßzeichnung Dimensional drawing Plan coté Габаритный чертеж M16x1.5 ø6 SW 27 G1/2 ø6 ø4 ETF 7 mit Schnellverschlussschrauben with quick-locking screws avec vis de fermeture rapide с быстрозаворачиваемыми винтами...
  • Page 3 THERMASGARD ® ETF 7 Rev. 2016 - V11 DE Sehr schnell ansprechendes Einschraubwiderstandsthermometer ⁄ Tauchtemperaturfühler 1x Zweileiterschaltung ® THERMASGARD ETF 7 mit passivem Ausgang, mit Halsrohr und einfach verjüngtem Schutzrohr Standard aus Edelstahl, Gehäusedeckel mit Schnellverschlussschrauben. Sehr schnelle Reaktionszeit, speziell geeignet bei sehr flinken Temperatur- bzw.
  • Page 4 Allgemeine Informationen Rev. 2016 - V11 DE Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorlie- genden technischen Parameter der Thermometer mit den realen Anschluss der Geräte darf nur an Sicherheitskleinspannung er- Einsatzbedingungen zu erfolgen, insbesondere: folgen.
  • Page 6 THERMASGARD ® ETF 7 Rev. 2016 - V11 GB Very quickly responding screw-in resistance thermometer ⁄ immersion temperature sensor 1x two-wire connection ® THERMASGARD ETF 7 with passive output, neck tube and a single-tapered stainless steel protective Standard tube, enclosure cover with quick-locking screws, very short reaction time, particularly suitable for very quick temperature changes and control operations, e.g.
  • Page 7 General notes Rev. 2016 - V11 GB Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Mounting and Installation Devices are to be connected under dead-voltage condition. Devices Before mounting, make sure that the existing thermometer‘s techni- cal parameters comply with the actual conditions at the place of must only be connected to safety extra-low voltage. Consequential utilization, in particular in respect of: damages caused by a fault in this device are excluded from war- ranty or liability.
  • Page 9 THERMASGARD ® ETF 7 Rev. 2016 - V11 FR Thermomètre à résistance à visser ⁄ sonde de température à plongeur THERMASGARD ® ETF 7 à 1 x 2 fils réaction ultrarapide avec sortie passive, tube prolongateur et tube de protection à simple diminution de Standard section à...
  • Page 10 Généralités Rev. 2016 - V11 FR Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11 Montage et installation Les raccordements électriques doivent être exécutés HORS Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux TENSION. Veillez à ne brancher l’appareil que sur un réseau de très basse tension de sécurité. Nous déclinons toute responsabi- conditions d’utilisation réelles, notamment : lité...
  • Page 12 THERMASGARD ® ETF 7 Rev. 2016 - V11 RU THERMASGARD ® ETF 7  – быстросрабатывающий ввинчиваемый термометр сопротивления / 1x Двухпроводное подключение погружной датчик температуры с пассивным выходом, горловиной и одноступенчатым сужением стандартное защитной трубки из высококачественной стали, крышкой корпуса с быстрозаворачиваемыми винтами. Очень...
  • Page 13 Указания к продуктам Rev. 2016 - V11 RU Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные...
  • Page 14 Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Под- Монтаж следует осуществлять с учетом соответствия прилагаемых тех- ключение должно осуществляться исключительно к безопасно нических параметров термометра реальным условиям эксплуатации, малому напряжению. Повреждения приборов вследствие несо- в особенности: блюдения упомянутых требований не подлежат устранению по –...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 91-210 (KP10) °...