RF Troubleshooting Instructions
Troubleshooting diagram for GSM900 receiver
Troubleshooting flow
Figure 34 GSM900 receiver troubleshooting
Results
By measuring with an oscilloscope at RXIP or RXQP on a working GSM900 receiver this picture should be seen.
Signal amplitude peak-peak 108mV. DC offset 1.0V.