Problem: Air pressure of spray appears low:
1. Clean the liquid filter assembly. See "The Liquid Filter Assembly".
2. Make sure that the liquid filter assembly is installed correctly. See Diagram 3 on p. 12.
3. Make sure that the air filter is installed correctly. See Diagram 2 on p. 11.
4. Clean the air filter. See "The Air Filter".
5. Clean the trigger. See "To Clean the Trigger".
Problem: No spray comes out of the nozzle or spray is erratic:
1. Make sure that the air pressure regulator is set between 12-15 psi.
2. Make sure that water temperature is at least 50° (10°C).
3. Make sure that all liquid fittings and air fittings are tight.
4. Clean the liquid filter assembly. See "The Liquid Filter Assembly"
5. Clean the nozzle assembly. See "The Nozzle Assembly".
6. Clean the trigger. See "To Clean the Trigger:.
Problem: Charging indicator blinks or goes out during operation:
1. Change the batteries. See "The Batteries".
2. Clean the Nozzle. See "The Nozzle Assembly".
Problem: Air compressor will not start:
1. Make sure that the electrical cord is plugged in an appropriate receptacle.
2. Make sure that the switch on the side of the air compressor is on.