"Gloss Boss" Burnisher GB-1090F (UHS20F)
This burnisher is a high quality, precision made product. All parts used in the manufacturing of this
burnisher have passed rigid quality control standards prior to assembly, and an "each unit" final inspection
prior to packaging is your assurance of proper assembly. This burnisher was protectively packed to
prevent possible damage in transit. Should damage occur, please notify the transporting carrier immedi-
ately for loss and/or claim.
GROUNDING:
This burnisher must be grounded while in use to protect the opera-
tor from electric shock. The burnisher is equipped with an approved
three-conductor cord and three-prong grounding type plug to fit the
proper grounding type receptacle. The green (or green and yellow)
conductor in the cord is the grounding wire. Never connect the green
(or green and yellow) wire to a live terminal.
If your unit is for use on less than 150
volts, it has a plug like that shown in
Figure A.
If it is for use on 150 to 250 volts, it has a
plug like that shown in Figure D.
An adapter (Figures B&C) is available for connecting Figure A plugs
to two-prong receptacles. The green-colored rigid ear, lug etc., must
be connected to a permanent ground such as a properly grounded
outlet box. No adapter is available for a plug as shown in Figure D.
Adapter shown in Figure B & C is not for use in Canada.
WARNING
RISK OF EXPLOSION.
sive mixture of fine dust and air. Use floor-sanding machine only
in a well ventilated area free from any flame or match.
RISK OF FIRE.
Do not use with a flammable or combustible
liquid to clean a floor.
Operation & Care Instructions
Save For Future Reference
IMPORTANT SAFEGUARDS
Floor sanding can result in an explo-
MOTOR:
This burnisher is powered by a 1-1/2 HP AC motor and will operate
on a 115 VAC 60HZ only. Be sure your power supply agrees with the
voltage marked on the name plates. A voltage decrease of more than
10% will cause the motor to slow down, thus increasing the current
draw and opening the circuit breaker.
EXTENSION CORDS:
Burnishers that have 3 wire cords requiring grounding must only be
used with extension cords that have 3-prong grounding type plugs
and 3-pole receptacles.
To determine the minimum wire size required, refer to the chart
below:
Minimum Wire Size (AWG) of Extension Cord
Nameplate
Total Extension Cord Length (Feet)
Rating-Amps
25
50
0-10.0
18
18
10.1-13.0
16
16
13.1-15.0
12
12
Before using an extension cord, inspect it for loose or exposed wires,
damaged insulation and defective fitting.
CAUTION
Always disconnect power cable from outlet
when working on this burnisher.
75
100 125 150 175 200
16
16
14
14
12
14
14
14
12
12
12
12
12
12
12
12
12
–
Need help?