Lock the grinding spindle with the spindle lock button (1)
before clamping and releasing the abrasive tools.
Do not press the spindle lock button while the grind-
u
ing spindle is moving. The power tool may become dam-
aged if you do this.
Quick-clamping nut
To change the abrasive tool easily without having to use any
additional tools, you can use the quick-clamping nut (14) in-
stead of the clamping nut (13).
The quick-clamping nut (14) may be used only for
u
grinding or cutting discs.
Only use quick-clamping nuts (14) that are in good work-
ing order and not damaged.
When screwing on, make sure that the printed side of the
quick-clamping nut (14) is not facing the grinding disc;
the arrow must be pointing towards the index mark (29).
(29)
Grinding/Cutting Disc
Pay attention to the dimensions of the grinding tools. The
mounting hole diameter must fit the mounting flange without
play. Do not use reducers or adapters.
When using diamond cutting discs, pay attention that the
direction-of-rotation arrow on the diamond cutting disc and
the direction of rotation of the machine (see direction-of-ro-
tation arrow on the machine head) agree.
See graphics page for the mounting sequence.
To fasten the grinding/cutting disc, screw on the clamping
nut (13) and tighten with the two-hole spanner.
After fitting the abrasive tool, check that the abrasive
u
tool is fitted correctly and can turn freely before
switching on the power tool. Make sure that the abras-
Bosch Power Tools
Press the spindle lock but-
ton (1) to lock the grinding
spindle. To tighten the
quick-clamping nut, turn
the grinding disc firmly
clockwise.
If the quick-clamping nut
has been attached correctly
and is not damaged, you
can loosen it by hand by
turning the knurled ring an-
ticlockwise. If the quick-
clamping nut is stuck, do
not attempt to loosen it
with pliers – always use
the two-pin spanner. Posi-
tion the two‑pin spanner as
shown in the figure.
ive tool does not brush against the protective guard or
other parts.
Flap disc
Always fit the hand guard (19) when working with the
u
flap disc.
Rubber sanding pad
Always fit the hand guard (19) when working with the
u
rubber sanding pad (20).
See the graphics page for fitting instructions.
Screw on the round nut (22) and tighten with the two-pin
spanner.
Cup brush/disc brush
Always fit the hand guard (19) when working with the
u
cup brush or disc brush.
See the graphics page for fitting instructions.
The cup brush/disc brush must be screwed onto the grinding
spindle until it rests firmly against the grinding spindle flange
at the end of the grinding spindle thread. Tighten the cup
brush/disc brush with an open-ended spanner.
Approved abrasive tools
You can use all the abrasive tools mentioned in these operat-
ing instructions.
-1
The permissible speed [min
] or the circumferential speed
[m/s] of the abrasive tools used must at least match the val-
ues given in the table.
It is therefore important to observe the permissible rota-
tional/circumferential speed on the label of the abrasive
tool.
Max. [mm]
D
b
180
8
230
8
180
230
100
30
M 14 /
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
English | 11
[mm]
-1
d
[min
]
[m/s]
22.2
8500
80
22.2
6500
80
8500
80
6500
80
8500
45
5/8"
1 609 92A 6ER | (10.05.2022)