Installation

Electrical connection

All work on the electrical
connection must be carried out by
the Miele Customer Service
Department, an authorised Miele
dealer or a qualified electrician.
- The electrical installation must be in
compliance with current local and
national safety regulations
(DIN VDE 0100 in Germany).
- The connection to the power supply
must comply with national
regulations (plug and socket must be
accessible after the appliance has
been installed). An electrical safety
test can then easily be carried out,
e.g. after any service or maintenance
work.
- If the dishwasher is hard wired to the
power supply, connection should be
made via a mains switch with all-pole
isolation. The mains switch must
ensure a gap of at least 3 mm
between all open contacts and must
be able to be locked in the off
position.
- Equipotential bonding should be
carried out if required.
- If replacing the mains cable, use only
original Miele spare parts or a
suitable cable with core cable ends.
- For technical data, see the data plate
or wiring diagram supplied.
The dishwasher must only be operated
with the voltage, frequency and fuse
rating shown on the data plate.
82
This appliance can be converted to a
different type of power supply in
accordance with the conversion
diagram and wiring diagram supplied.
Converting the appliance to a
different type of power supply can
lead to longer programme running
times, resulting in increased energy
consumption.
The declared consumption values
will only be achieved if the appliance
remains in the state in which it was
delivered.
The data plates (with VDE test
certificate, etc.) are located at the back
of the dishwasher and on the inner
panel of the door.
The wiring diagram is supplied with
the dishwasher.
The conversion diagram is attached to
the electrical connection plinth panel.
Equipotential bonding connection
There is a screw connection point
marked  at the back of the appliance,
to which additional equipotential
bonding can be connected.