Carrier 130 Series Installation, Start-Up, And Operating Instructions Manual page 20

Upflow/ horizontal variable speed 2-stage, induced-combustion gas furnace
Table of Contents

Advertisement

AC/HP JUMPER POSITION: HP—CMFT, HEAT PUMP—COMFORT, HEATING AIRFLOW
Airflow
Selection
Furnace Size
Cool Size
Jumper
Position
LO
M-LO
060
M-HI
HI
LO
M-LO
080
M-HI
HI
LO
M-LO
100**
M-HI
HI
LO
M-LO
120**
M-HI
HI
* Minimum airflow is set for electronic air cleaner: 060—500 CFM, 080—500 CFM, 100—700 CFM, 120—700 CFM
** Air delivery may be reduced by as much as 3 percent when using a single side return.
NOTE:
Continuous-fan settings are 50 percent, 65 percent, or 100 percent of selected cooling airflow.
c. Verify furnace model. Table 11 can only be used for model
58UHV/58UXV Furnaces.
d. Find installation altitude in Table 11.
NOTE: For Canada altitudes of 2000 to 4500 ft, use U.S.A.
altitudes of 2001 to 3000 ft in Table 11.
e. Find closest natural gas heat value and specific gravity in
Table 11.
f. Follow heat value and specific gravity lines to point of
intersection to find orifice size and low- and high-heat
manifold pressure settings for proper operation.
EXAMPLE: (0—2000 ft altitude)
Heating value = 1075 Btu/cu ft
Specific gravity = 0.62
Therefore: Orifice No. 45
Manifold pressure:
*Furnace is shipped with No. 45 orifices.
In this example, all main burner orifices are the correct size and
do not need to be changed to obtain proper input rate.
DO NOT redrill orifices. Improper drilling (burrs, out-of-
round holes, etc.) can cause excessive burner noise and
misdirection of burner flames. This can result in flame
impingement of burners and heat exchangers, causing fail-
ures. (See Fig. 21.)
g. Check and verify burner orifice size in furnace. NEVER
ASSUME ORIFICE SIZE; ALWAYS CHECK AND
VERIFY.
3. Adjust manifold pressure to obtain input rate.
Table 10—Heat Pump Comfort Heating Nominal CFM
At Up to 0.70-in. w.c. ESP (With Filter)
Single-Speed
CFM
Cool CFM Per Ton
Jumper Position
Tons
400
350
1-1/2
540
500*
2
720
630
2-1/2
900
790
3
1080
945
2-1/2
900
785
3
1080
945
3-1/2
1260
1100
4
1440
1260
3
1075
940
3-1/2
1260
1100
4
1440
1260
5
1900
1575
3
1045
945
3-1/2
1260
1100
4
1440
1255
5
1800
1575
3.4-in. wc for high heat
1.4-in. wc for low heat
Two-Speed (High/Low)
Cool CFM Per Ton Jumper Position
400
315
High
Low
500*
565
500*
570
780
500*
710
945
585
755
1135
700
710
945
605
850
1135
715
990
1325
830
1135
1510
940
855
1130
700
990
1325
820
1130
1510
935
1420
1890
1170
860
1075
780
980
1280
875
1125
1485
965
1410
1900
1170
a. Remove caps that conceal adjustment screws for low- and
high-heat gas valve regulators. (See Fig. 22.)
b. Move setup switch SW-2 on control to ON position. (See
Fig. 18.) This keeps furnace locked in low-heat operation.
c. Jumper R and W/W1 thermostat connections on control to
start furnace.
d. Turn low-heat adjusting screw (5/64 hex Allen wrench)
counterclockwise (out) to decrease input rate or clockwise
(in) to increase input rate.
NOTE: DO NOT set low-heat manifold pressure less than 1.3-in.
wc or more than 1.7-in. wc for natural gas. If manifold pressure is
outside this range, change main burner orifices.
DO NOT bottom out gas valve regulator adjusting screw.
This can result in unregulated manifold pressure and result in
excess overfire and heat exchanger failures.
NOTE: If orifice hole appears damaged or it is suspected to have
been redrilled, check orifice hole with a numbered drill bit of
correct size. Never redrill an orifice. A burr-free and squarely
aligned orifice hole is essential for proper flame characteristics.
e. Move setup switch SW-2 to OFF position after completing
low-heat adjustment.
f. Jumper R and W2 thermostat connections on control center.
(See Fig. 15.) This keeps furnace locked in high-heat
operation.
g. Turn high-heat adjusting screw (5/64 hex Allen wrench)
counterclockwise (out) to decrease input rate or clockwise
(in) to increase rate.
NOTE: DO NOT set high-heat manifold pressure less than 3.2-in.
wc or more than 3.8-in. wc for natural gas. If manifold pressure is
outside this range, change main burner orifices.
20
CFM
350
315
High
Low
High
500*
500*
500*
660
500*
595
830
515
740
990
610
895
825
535
1040
990
630
1190
1150
725
890
1325
825
1040
980
700
1190
1155
750
1490
1350
825
885
1655
1035
1035
975
750
750
1140
790
790
1320
880
880
1650
1025
1025
Low
500*
500*
500*
555
500*
560
655
740
700*
700*
740
920
750
760
835
970

Advertisement

Table of Contents
loading

This manual is also suitable for:

58uhv58uxv

Table of Contents