Technical data
Control box
Mains voltage
Mains frequency
Power absorption
Safety class
Load on
Fuse on the control box (can be inspected)
'input' terminals
Undervoltage
–
–
Cable length
–
–
–
–
–
–
Environmental
Storage
conditions
–
–
–
–
Transport
–
–
–
–
Operation
–
–
–
–
Condensation, the formation of ice and the entry
of water are prohibited!
WARNING
Technical description of the burner
Safety switch-off from operating position to mains
voltage
Restart when mains voltage picks up
Main line AC 230 V
Control load (TL1-TL2)
External reset button (RS)
Load exit (DC 0/2...10V)
Fuel valve
Other lines
Climatic conditions
Mechanical conditions
Temperature range
Humidity
Climatic conditions
Mechanical conditions
Temperature range
Humidity
Climatic conditions
Mechanical conditions
Temperature range
Humidity
AC 230 V -15% / +10%
50 / 60 Hz ±6%
< 30 W
I, with components in compliance with II and III, ac-
cording to DIN EN 60730-1
6.3 AT
< AC 186V
> AC 195V
Max. 100 m (100 pF / m)
Max. 20 m (100 pF/m)
Max 20 m (100 pF/m)
Max. 10 m (100 pF/m)
Max. 3 m (100 pF/m)
Max. 3 m (100 pF/m)
DIN EN 60721-3-1
Class 1K3
Class 1M2
-20 ... +60 °C
< 95% RH
DIN EN 60721-3-2
Class 2K2
Class 2M2
-30 ... +60 °C
< 95% RH
DIN EN 60721-3-3
Class 3K3
Class 3M3
-20 ... +60 °C
< 95% RH
GB
17
Tab. I
20079029