FEATURES

FEATURES

  • TIME / CALENDAR
  • SINGLE-TIME ALARM
    Can be set to ring only once at a designated time within the coming 12 hours.
  • STOPWATCH
    Measures up to 60 minutes in 1/5 second increments.
    Split time measurement

SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION

  • This watch is so designed that the following are all made with the crown at the second click position
  1. main time setting
  2. alarm hand adjustment
  3. stopwatch hand position adjustment

Once the crown is pulled out to the second click, be sure to check and adjust 1) and 2) at the same time. if needed, 3) should also be adjusted then.
CROWN: Pull out to second click when the second hand is at the 12 o'clock position.

MAIN TIME SETTING

MAIN TIME SETTING
CROWN: Turn to set the hour and minute hands.

  1. When the stopwatch is or has been measuring, if the crown is pulled out to the second click, it will automatically reset the STOPWATCH hands to "0".
  2. If the alarm has been set and the crown is pulled out to the second click, the ALARM hands will turn to indicate the current time.
  3. It is recommended that the hands be set to the time a few minutes ahead of the current time, taking into consideration the time required to set the ALARM hands and to adjust the STOPWATCH hand position if necessary.
  4. When setting the hour hand, be sure to check that AM/PM is correctly set. The watch is so designed that the date changes once in 24 hours.
  5. when setting the minute hand, first advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact minute.

ALARM HAND ADJUSTMENT

ALARM HAND ADJUSTMENT

Set the ALARM hands to the time the main time hands indicate
B: Press repeaedly to set ALARM hands to the time indicated by the main time hands.
* The ALARM hands move quickly if button B is kept pressed.

STOPWATCH HAND POSITION ADJUSTMENT

If the STOPWATCH hands are not in the "0" position, follow the procedure below to set them to the "0" position.

  1. Press for 2 second.
    *STOPWATCH minute hand turns a full circle.
  2. Press repeatedly to set STOPWATCH minute hand to the "0" position.
    *The hand moves quickly if button B is kept pressed.
  1. Press for 2 second.
    * STOPWATCH 1/5-second hand turns a full circle.
  2. Press repeatedly to set STOPWATCH 1/5second hand to the "0" position.
    * The hand moves quickly if button B is kept pressed.
  • ALARM and STOPWATCH hands can be readjusted in the following order by pressing button A for 2 seconds.
    STOPWATCH HAND POSITION ADJUSTMENT
    CROWN: Push back in to normal position in accordance with a time signal
    *After all the adjustments are completed, check that the main time and alarm hands indicate the same time

SETTING THE DATE

  • Before setting the date, be sure to set the main time.

    CROWN
    Pull out to first click.

    Turn clockwise until the desired date appears.

    Push back in to normal position.
  1. It is necessary to adjust the date at the end of february and 30-day months.
  2. do not set the date between 9:00 p.m. and 1:00a.m. Otherwise, the date may not change properly.
  3. Do not press button B when the crown is at the first click position, as this will move the ALARM hands.

STOPWATCH

  • The stopwatch can measure up to 60 minutes in 1/5-second increments.
  • After 60 minutes, it will start counting again from "0" repeatedly up to 12 hours.
    Using the STOPWATCH

Before using the stopwatch, be sure to check that the crown is set at the normal position and that the STOPWATCH hands are reset to the "0" position.
* If the STOPWATCH hands do not return to the "0" position when the stopwatch is reset to "0", follow the procedure in "SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION".

STOPWATCH - Standard measurement
Standard measurement

STOPWATCH - Accumulated elapsed time measurement
* Restart and stop of the stopwatch can be repeated by pressing button A.
Accumulated elapsed time measurement

STOPWATCH - Split time measurement
* Measrement and release of split time can be repeated by pressing button B.
Split time measurement

STOPWATCH - Measurement of two competitors
Measurement of two competitors

SINGLE-TIME ALARM

  • The alarm can be set to ring only once at a designated time within the coming 12 hours.
  • The alarm time can be set in one minute increments.

ALARM TIME SETTING

Before using the alarm, check that the ALARM hands are adjusted to the current time. (See " SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION")

CROWN: Pull out to first click.

B: Press repeatedly to set the desired alarm time.
* The ALARM hands move quickly if button B is kept pressed.

CROWN: Push back in to normal position.
* The alarm is automatically engaged.

  1. The single-time alarm cannot be set for a time more than 12 hours ahead of the current time. While you keep button B pressed to advance the ALARM hands quickly, they stop when they indicate the current time and the alarm is disengaged. In that case, release button B, and then, press and hold the button again to set the ALARM hands to the desired time.
  2. While the crown is at the normal position, the ALARM hands indicate the current time when the alarm is disengaged and the designated alarm time when it is engaged.

HOW TO STOP THE ALARM

At the designated time the alarm rings for 20 seconds, and it is automatically disengaged as it stops. To stop it manually, press button A or B.

  1. While the stopwatch is measuring, the alarm rings differently than usual. Hower, this is not a malfunction.
  2. While the alarm is ringing, pressing button A or B will only stop the alarm, and no stopwatch operation can be made.

HOW TO CANCEL THE ALARM TIME YOU HAVE SET

CROWN: Pull out to first click.

B: Press and hold until ALARM hands stop and indicate the current time.

CROWN: Push back in to normal position.

* To correct the alarm time you have set, follow the procedure described in " ALARM TIME SETTING"

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Pulsar Calibre YM62 - Analog Quartz Chronograph Manual

Advertisement

Need help?

Need help?

Do you have a question about the YM62 and is the answer not in the manual?

Questions and answers

Table of Contents