ONE MK-E18 User Manual

Cold spark machine

Advertisement

Quick Links

PRODUCT: COLD SPARK MACHINE
MODEL: MK-E18
USER
MANUAL
VERSION 2.0

Advertisement

Table of Contents
loading

Summary of Contents for ONE MK-E18

  • Page 1 PRODUCT: COLD SPARK MACHINE MODEL: MK-E18 USER MANUAL VERSION 2.0...
  • Page 2 USER MANUAL (MK-E18) 1. PRECAUTIONS Dear customers: Thanks for choose our cold spark machines, pls read the user manual careful before used to get better user experience. 1)Due to the manual content limited, pls understand missed some of detail and safety direction in using, and not undertake the responsible of the use result for missing.
  • Page 3: Product Diagram

    AMAZING BOOSTER FOR STAGE 2. Product diagram Display Power port Spray hole Parameter Power switch Powder hole label DMX port Fuse Working Height 1-5m Control mode 360° Housing material Aluminum Fountain direc- tion Working Tem- -10-50 20kgs perature Power 1300W Dimension 365*365*400mm 110V/16A,...
  • Page 4: Operation Panel

    USER MANUAL (MK-E18) 3. Operation Panel 1)LCD Display Area 1---Means nozzle 1 fountain, the following number is heating temp. of nozzle 1. DMX/RF---Show “DMX”, then be controlled by console, the following number is DMX address code; If show “RF”, then in remote control mode.
  • Page 5 AMAZING BOOSTER FOR STAGE 3)Indicator Description READY: Green light When the “READY” green light always light on, can start to do fountain. DMX: Blue light Flashing shows that DMX signal is connected, otherwise no signal. FAULT: Yellow light: The light is on with any malfunction. HEAT: Red light When the machine is heating, signal light is on;...
  • Page 6: Dmx 512 Operation

    USER MANUAL (MK-E18) 1)DMX 512 Operation : 1.The machine adopts 3-pin signal wire connection, with DMX IN and DMX OUT double interfaces, which can be used for multiple connections and is suitable for standard 512 signal control. DMX control included two channel modes (common mode occupied 2 channel, professional mode occupied 4 channel).
  • Page 7 AMAZING BOOSTER FOR STAGE 4-channel common mode 1st channel Function 0-10 Pre-heat turn off 11-220 Emergency stop 221-239 Clear Powder 240-255 Pre-heat turn on 2nd channel Function (Nozzle 1) 0-15 Nozzle 1 fountain off 16-31 Not spin, Fountain 1 64-111 Not spin, Fountain 2 112-159 Not spin, Fountain 3...
  • Page 8 USER MANUAL (MK-E18) 64-111 Not spin, Fountain 2 112-159 Not spin, Fountain 3 160-207 Not spin, Fountain 4 208-255 Not spin, Fountain 5 4th channel Function (Spinning adjust) 0-15 Not spin 16-135 Clockwise spin (60-100BPM)
  • Page 9 AMAZING BOOSTER FOR STAGE 2.Console operation 1.Connect the power cable and DMX signal cable of machine, turn on green power button, DMX blue indicator light keep in flashing, means DMX signal connected successful. 2.The first channel push to top start heating, till the green indicator light always in lighting, then can do fountain.
  • Page 10 USER MANUAL (MK-E18) 1.Power(remote signal connect/unconnected): short press 1s con- nect to machines, the display will show from “DMX” become to “RF” if connected successful; long press 3s unconnected, display show “DMX”. 2.HEAT ON/OFF: after 1s do heating, red indicator will light, dis- play will show dynamic temperature value, till green indicator al- ways keep light on, then finished heat.
  • Page 11 AMAZING BOOSTER FOR STAGE 2)Remote Operation Connect/ Nozzle 2 not spin, 2 nozzles spin, Unconnected do high spray do high spray Nozzle 2 not spin, Nozzle 1 not spin, do Clear Powder do low spray high spray Nozzle 1 not spin, Stop spray HEAT ON/OFF do high spray...
  • Page 12: Clean And Maintenance

    USER MANUAL (MK-E18) 4. Clean and Maintenance Clear powder Pls empty the remaining consumables after used, and power on use Clear Powder process to clear the remaining material by remote controller or DMX controller. (Note: problems caused by improper cleaning will not be covered by the free war- ranty).
  • Page 13: After-Sales

    AMAZING BOOSTER FOR STAGE 6. After-sales Warranty1 Year (Subject to the date of manufacture) Each machine is affixed with the factory code. The factory code shall be provided when enjoying the warranty service. It is invalid if torn It’s may need provide some videos or pictures to confirm the problems.
  • Page 14: Warnings And Cautions

    USER MANUAL (MK-E18) 5. Warnings and Cautions Warning: High temperature warning, high temperature at exit. The sign is to remind users of paying attention to risk and security. Please note that the machines are not meant to be a continuous duration effect.
  • Page 15 AMAZING BOOSTER FOR STAGE 11)The machine built-in protection procedures, will stop auto. once do fountain over 30s each time. If need it to work again, please operate the second channel again. The continuous shooting time is too long, the internal temperature will rise sharply and cause per- manent damage.

Table of Contents