Operator Care - Wash Zone - Washtech CD240 Operator's Manual

Rack conveyor
Table of Contents

Advertisement

Operator Care – Wash Zone
CD240 Wash Zone
• Part #:
CD240 Wash Zone
• Date:
22/04/2022
• Version:
1-A
Daily Cleaning
Remove Scrap Trays (10) and clean with a brush and water to clear grid.
Remove Wash Pump Inlet Filter (12) and clean with a brush and water to clear grid.
Return Drain Upstand (11), Wash Pump Inlet Filter (12) and Scrap Trays (10) to the machine.
Weekly Cleaning
To be done in conjunction with Daily cleaning.
Remove Lower Wash Arms (8) – lift up to unhook the arm and then withdraw.
Remove Upper Wash Arms (7) – push the locking bar up and then withdraw.
Check to ensure arms are clear of obstructions. Remove end caps to clear if not.
Flush Arms (7 & 8) with water. Use a toothpick or paper clip if necessary to clear jets.
Return the Wash Pump Inlet Filter (12), the Drain Plug (11), Scrap Trays (10),
Lower Wash Arms (8) and Upper Wash Arms (7) to the machine.
12/5/2022
Washtech CD240L Operator Manual
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cd240l