CT4000
5
Installing the toilet
5.1
Installing the service door
Model-dependent installation instructions are included with the service door
( Dometic SK4, SK5).
I
NOTE
Prepare the feed-through for the vent hose at the desired location
(chapter "Venting the cartridge tank" on page 21).
5.2
Making wall cutouts
➤ Follow the instructions of the installation manual that comes with the service
door.
2
➤ Make a rectangular opening in the outer wall with the following dimensions
(fig. 2):
Service door wall cutout SK4:
– y = 25 mm
– b = 305 mm ± 1 mm
– h = 375 mm ± 1 mm
Service door wall cutout SK5:
– y
= 12.5 mm, y
min
– b = 310 mm ± 1 mm
– h = 360 mm ± 1 mm
The dimension x results from the placement of the toilet.
EN
b
x
= 28 mm
max
Installing the toilet
h
y
7