Quick Start - Basic Operation(All 3-Rail Models) - Rail King DRG 4-6-2 STEAMER Operating Instructions Manual

Table of Contents

Advertisement

QUICK START - BASIC OPERATION
The RailKing DRG 4-6-2 contains state-of-the art electronics with several
built-in automatic features for incredibly realistic operation. Despite these
advanced features, the DRG 4-6-2 is easy to operate with any compatible
standard AC transformer (see the compatibility chart on page 34). All
models are equipped with an operating smoke system that should be primed
with smoke fluid before operating. Adding 15 - 20 drops of fluid through
the smoke stack should be sufficient. If you choose to not prime the units
with fluid, turn the smoke unit switch located under the trailing truck to
the OFF position. (See Figure 3 on page 4) This will prevent any damage
from occurring to the smoke unit when running the engine without a primed
smoke unit. For more information see the section on page 4 on Smoke Unit
operation.
The DRG 4-6-2 model is controlled by a
ProtoSound® DCRU® electronic reverse
unit. The reverse unit operates in the same
manner that all reverse units function by
using forward, neutral and reverse states
that are entered each time the throttle is
turned on and off or by using the
transformer direction switch (if so equipped).
The reverse unit is designed to ignore dirty track, dead spots on switches
or minor short circuits without disrupting the engine operation, even at
RESET
Forward
Figure 2: ProtoSound® DCRU® Cycle Phases
the plug is inserted, the throttle on the transformer can be advanced. You
will see that only the engine's lights come on and that on ProtoSound®
equipped engines, two dings from the sound system will chime followed by
the steam compressor pump sounds. The engine does not run. This is
known as the RESET state and is explained in more detail beginning on
Page 5. The ProtoSound® DCRU® will not power the motor until the
throttle is turned OFF and then ON again. At this point, the engine will
now function just like any other electronic or mechanical E-unit.
Neutral
Reverse
Neutral
RailKing DRG 4-6-2 Operating Manual
Use 2nd Hole For Display and 96 Inch
or larger diameter curves
Figure 1: Plugging in the tender harness
slow, prototypical speeds. Before
the engine can be operated however,
the reverse unit plug that extends out
of the tender must be inserted into
the receptacle at the back of the
boiler cab as seen in Figure 1. Once
3
Plug Tender Plug Into
Boiler Socket At Back Of Cab
Use First Hole For O-72 Operation

Advertisement

Table of Contents
loading

Table of Contents