3 TECHNICAL DATA

TABLE 2/A
Nominal heat Input net QMS
Minimum heat Input net
Nominal heat output
Nominal heat output condensing
Minimum heat output
Minimum heat output condensing
Inlet pressure
20 mbar
Fan speed
Max 5200 rpm - 173 Hz
C.H.
min 1200 rpm - 40 Hz
Electrical supply: 230 V ~ 50 Hz
External fuse rating: 3 A
Dry weight : 31 Kg
Gas Supply Connection
Flow connection C.H.
Return connection C.H.
Safety discharge C.H.
Condensation drain
Max cold water capacity without additional expansion vessel
Sealed water system C.H.
Max pressure PHS
Minimum working pressure
7 Litres expansion vessel pre-charge-pressure
Central Heating operating temperature
Design fl ow rate
Minimum fl ow rate C.H.
Flue outlet nom. diameter 100 mm specially supplied with boilers (If required)
Destination: GB, IE
Flue Type: C13 - C33 - C53 - C63 - C83
LWA sound power level, indoors
ErP
Seasonal space heating energy effi ciency class
μs seasonal space heating energy effi ciency
Pn nominal heat input
P4 nominal heat output high temperature
P1 nominal heat output (30% Pn) low temperature
μ4 effi ciency at nominal heat output high temperature
μ1 effi ciency at 30% nominal heat output low temperature
Auxiliary electricity consumption:
elmax at full load
elmin at part load
14
HE 80 S System
NATURAL GAS (G 20) П
Gas rate after 10 minutes
Internal fuse F1: 3.15 A
Water content C.H.: 0.8 Litre
15 mm compression isolating valve
22 mm compression isolating valve
22 mm compression isolating valve
15 mm copper pipe
3/4" (21.5 mm) push fi t over fl ow
Max 80 °C
Category: II2H3P
50.5 dB
91.4 %
21.0 kW
20.4 kW
3.5 kW
0.034 kW
0.016 kW
21.0 kW
3.7 kW
20.4 kW
22.1 kW
3.5 kW
3.9 kW
Max 2.1 m
Combustion % CO
: 9.0 (+ 0.5 / - 0.5) Case On
2
(20 mm To BS 4265)
Water content D.H.W.: 0.2 Litre
110 Litre
2.5 bar
0.5 bar
0.5 bar
min 35 °C
1066 I/h 20 °C rise
350 l/h
SEDBUK A
NO
class 5 - 24.40 mg/kWh
x
87.3 %
97.0 %
PSB in standby mode
Pstby standby heat loss
2H3P
/h - min. 0.4 m
3
9.0 (+ 0.5 / - 0.5) Case Off
Electrical protection index: IP X4 D
/h
3
0.005 kW
0.056 kW