Ebyte E78-DTU User Manual page 35

Table of Contents

Advertisement

command
character
CRX1DELAY
set the
(
number of
times to send
command
character
CSAVE
Save MAC
(
parameter
settings
)
command
character
CRESTORE
restore MAC
(
default
parameters
)
Copyright©2012–2023, Chengdu Ebyte Electronic Technology Co., Ltd.
OK
Needs to be setup before sending data. Do not set the default value
Precautions
command
command format
type
test
AT+CRX1DELAY=?
command
query
AT+CRX1DELAY?
command
set
AT+CRX1DELAY=<Delay>
command
Parameter
Description
Delay: how long to open the RX1 window after sending, unit: s;
)
Return value
description
AT+CRX1DELAY=2
example
OK
Set how long to open the RX1 window after sending, set before sending data. It is
Precautions
the protocol default value when not set.
command
command format
type
test
AT+CSAVE=?
command
set
AT+CSAVE
command
Parameter
Description
<MType>: 0: unconfirm package, 1: confirm package.
Return value
<value>: It is the maximum sending times, value range: 1~15;
description
This command saves the configuration parameters to EERPOM/FLASH.
example
After executing the AT+RESET command, the module will use the new MAC
configuration parameters for network initialization and operation.
Precautions
Need to save before sending data
command
command format
type
test
AT+CRESTORE=?
command
set
AT+CRESTORE
command
Parameter
This command restores MAC default configuration parameters to
Description
EERPOM/FLASH.
response
+CRX1DELAY: " Delay "
OK
+CRX1DELAY:<Delay>
OK
OK
response
+CSAVE
OK
OK
response
+CRESTORE
OK
OK
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

900ln22

Table of Contents