command
character
CAPPSKEY
( Set AppSKey )
command
character
CNWKSKEY
set NwkSKey
(
Copyright©2012–2023, Chengdu Ebyte Electronic Technology Co., Ltd.
query
AT+CDEVADDR?
command
set
AT+CDEVADDR=<value>
command
Parameter
Description
Return
<value>: Node DevAddr
value
description
AT+CDEVADDR=00112233
example
OK
Used in ABP, set or read DevAddr, return Y1Y2 ... Y4, hexadecimal format, value 4
Precautions
bytes.
command
command format
type
test
AT+CAPPSKEY=?
command
query
AT+CAPPSKEY=<value>
command
set
AT+CDEVADDR=<value>
command
Parameter
Description
<value>: Node AppSKey
Return
value
description
AT+CAPPSKEY=AABBCCDD00112233AABBCCDD00112233
example
OK
Used in ABP, set or read AppSKey, return Y1Y2 ... Y16, hexadecimal format, value
Precautions
16 bytes.
command
command format
type
test
AT+CNWKSKEY=?
command
query
AT+CNWKSKEY?
command
set
AT+CNWKSKEY=<value>
command
)
Parameter
Description
Return
<value>: Node NwkSKey
value
description
+CDEVADDR:<value>
OK
OK
response
+CAPPSKEY=<AppSKey:length is 32>
+CAPPSKEY:<value>
OK
OK
response
+CNWKSKEY=<NwkSKey: length is 32>
+CNWKSKEY:<value>
OK
OK
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

900ln22

Table of Contents