for the communication of the CAN bus. Before communication, you need to determine the baud rate of the target device
or the target bus. Support 5k-1000k , support custom baud rate.
If you are using a special baud rate, please click the Customize button. At this time, you need to enter a decimal baud rate.
The following table lists the values of some special baud rates. Select a suitable configuration.
Please note that it is especially important to set the baud rate. Many customers report that there is no data after the device
is connected, or the bus is wrong. In fact, the baud rate is not set, so click OK to open the device. Here to remind you,
whether you use our device as a master or a slave device, as long as you connect the device to the CAN bus, you must set
the baud rate of the device to be consistent with the baud rate of the target device before it can work normally.
Open channel button: You can open the CAN channel here.
4
After the device parameters are set, the software will enter the working state. If there is data on the bus, the data will be
displayed in the receive data window. The receiving window is shown in the following figure: