Eaton 57600-401 Installation And Operation Manual
Eaton 57600-401 Installation And Operation Manual

Eaton 57600-401 Installation And Operation Manual

10-15 vdc, 115/230 vac, red display

Advertisement

Durant
AMBASSADOR SERIES COUNT CONTROL
MODELS:
57600-401 (10-15 VDC)
57601-401 (115 VAC)
57602-401 (230 VAC)
5760X-451 (Red Display)
• Six Digit, Single Preset Counter
• 1/Tau Rate Meter
• Counter and Rate Meter Scaling
• Four User-Configurable Control Inputs
• One Output Relay
• Two Solid State Outputs
• RS-485 Serial Communications
• Choice of Green or Red Display

TABLE OF CONTENTS

1
3
4
5
12
13
15
Wiring Diagrams
18
24
Diagnostics and Troubleshooting
26
27
Durant
®
INSTALLATION AND OPERATION
MANUAL Number 57600-901-05
Durant
®
C 123456
P1 10000
RST
RUN
HELP
CLR
PGM
EXIT
ENT
SEL
N A E D
ASSOCIATE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 57600-401 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton 57600-401

  • Page 1: Table Of Contents

    Durant INSTALLATION AND OPERATION MANUAL Number 57600-901-05 AMBASSADOR SERIES COUNT CONTROL N A E D MODELS: ASSOCIATE 57600-401 (10-15 VDC) 57601-401 (115 VAC) 57602-401 (230 VAC) 5760X-451 (Red Display) • Six Digit, Single Preset Counter • 1/Tau Rate Meter Durant ®...
  • Page 2: Introduction

    INTRODUCTION GENERAL DESCRIPTION MENU PROGRAMMING The Durant Ambassador 5760X-401 is a six digit single Another unique feature of the Ambassador family of counters preset count control device with four programmable inputs, is the menu driven programming. The two line alpha- numeric three outputs, and a built in rate meter.
  • Page 3 BLOCK DIAGRAM/OVERVIEW Pick Inp 1 RELAY 1 OUTPUT Drop Inp 2 LOGIC Inp 3 Inp 4 Pick Count Signal TRANSISTOR Preset COUNT 1 OUTPUT COUNTER Drop SCALER LOGIC From Sensor(s) Pick RATE METER (Rate Scaling) TRANSISTOR 2 OUTPUT Drop LOGIC COUNT SCALER PROGRAMMABLE INPUTS Receives the up or down signals and adds or subtracts the...
  • Page 4: Front Panel Features

    FRONT PANEL FEATURES Durant ® C 123456 Two line LCD Display - Shows count, preset, and rate values when unit is in the run mode. Displays P1 10000 programming information when the unit is in the program mode. HELP EXIT Key Functions Reset/Clear Key - In the run mode this key Exit Key - In the preset editing mode this key...
  • Page 5: Run Mode Operation

    RUN MODE OPERATION SELECTING DISPLAY INFORMATION CHANGING PRESET VALUES This Ambassador control has three available run mode The preset value is set as follows: displays. Use the up and down arrow keys to select the desired display. 1. Use the up and down arrow keys to select the preset screen.
  • Page 6 PROGRAM MODE INTRODUCTION TO MENU PROGRAMMING ENTERING THE PROGRAM MODE The menu programming format used by the Ambassador series eliminates the need to memorize or look up program- To enter Then ming options. Program prompting is provided on the 2 line Press program alphanumeric display.
  • Page 7 PROGRAMMING SCALERS AND COUNT INPUTS See pages 10-11 for detailed description of MAIN MENU SUB MENU EDIT MENU programming options. to exit to press EXIT main menu Data field flashes press press SEL selects digit to be programmed PROGRAM C SCALER C SCALER from left to right.
  • Page 8: Programming

    PROGRAMMING CONTROL INPUTS See pages 10-11 for detailed description of MAIN MENU SUB MENU EDIT MENU programming options. to exit to press EXIT main menu press press Data field flashes Define input function from the PROGRAM INPUT 1 INPUT 1 EXIT list provided.
  • Page 9 PROGRAMMING OUTPUTSPROGRAMMING CONTROL INPUTS MAIN MENU SUB MENU VIEW MENU EDIT MENU to exit to to exit to press press EXIT EXIT Data field flashes main menu sub menu press press RELAY 1 RELAY 1 PROGRAM RELAY 1 RELAY 1 EXIT NORMAL REVERSE...
  • Page 10 PROGRAMMING SERIAL PORT AND OPTIONS See pages 10-11 for detailed description of MAIN MENU SUB MENU EDIT MENU programming options. to exit to press EXIT main menu Data field flashes press press PROGRAM SER PORT SER PORT Program two digit serial port address. (Must be in a range from 00-99) SER PORT EXIT...
  • Page 11 DESCRIPTION OF PROGRAM OPTIONS SCALERS RESET TO ZERO — the counter resets to zero when a counter reset occurs. The normal count direction is up and C SCALER — the count scaler determines the value of each the counter outputs respond only when counting up. input pulse.
  • Page 12 DESCRIPTION OF PROGRAM OPTIONS OUTput MODE PARITY — the user may select none, odd, or even parity. If none (no parity) is selected, the counter transmits space RELAY 1 NORMAL — relay 1 turns on when it receives a parity and does not check received parity. pick-up signal and turns off when it receives a drop-out signal.
  • Page 13: Scale Factors

    CALCULATING SCALE FACTORS COUNT SCALING RATE SCALING The count scaler is a user programmable number which The 1/Tau rate meter calculates rate by measuring the time determines the count value of each input pulse. It is used to interval between input pulses, converting to frequency, and correct for a known amount of error (wheel wear, viscosity, multiplying by the rate scaler.
  • Page 14: Rear Terminal Description

    On the model 57600 this terminal is used for the 10-15 VDC Model 57602-401 230VAC power input. Connect the positive lead of the power supply to Model 57600-401 Not used terminal 1 and the negative lead to DC Common. 13, 14 - Transistor Outputs 2 and 1: These terminals are The DC POWER OUTPUT contains a series Positive Tem- separate open collector NPN transistor outputs.
  • Page 15 REAR TERMINAL DESCRIPTION CONTINUED MODULAR COMMUNICATION JACK Switch 2: Input B sink/source Off: input B requires a current sinking input signal. The modular phone jack is an alternate connection to the RS- On: input B requires a current sourcing input signal. 485 communications port.
  • Page 16 AC WIRING/CONTACT INPUT WIRING AC Power Input (AC Models Only) Terminal 4 (Ground) and terminals 2 and 3 (Com) are internally connected. Check part number on counter Fuse Size label to verify correct voltage AC Power In U.S. European rating. 115 V, 60 Hz 1/8 amp T125 mA, 250 V...
  • Page 17 COUNT INPUT WIRING Current Sinking Sensor Current sinking (open Count Input collector NPN transistor) sensor output Do not connect Term 1 if sensor is Count Black Signal powered from another power supply. Wire colors shown correspond to Cutler-Hammer inductive proximity and photo sensors.
  • Page 18 ENCODER WIRING/OUTPUT WIRING Shaft Encoder Wiring (Encoder Pin D) Blue Do not connect Term 1 if sensor is (Encoder Pin E) Yellow powered from another power supply. Wire colors shown are for Shaft Encoder quadrature encoder, do not connect Durant Pt # the yellow wire for a single channel encoder.
  • Page 19 INTRODUCTION TO SERIAL COMMUNICATIONS The advanced communication capability of the Ambassador SERIAL COMMAND FORMAT control allows a host computer to read and reset the counter, read and write the preset, inhibit and enable counts, turn The general command format is shown below. Spaces are used for clarity only and must not be transmitted.
  • Page 20 SERIAL COMMAND/RESPONSE FORMAT 4. Numeric data required with the RCD command to specify Error Codes: counter or preset to be read. Up to eight numeric charac- 00 - Power up Error — When power is applied to the unit, or ters are required for some commands.
  • Page 21 SERIAL COMMANDS RCD7 is a special command that sends all of the values that These commands mimic the stop count input function. When have been specified in the SERIAL OUTPUT menu. The the counter receives an STP command, all count input pulses counter sends values in the order shown above.
  • Page 22: Serial Communications

    SERIAL COMMUNICATIONS SERIAL PROGRAM-MODE COMMANDS SAMPLE COMMUNICATIONS PROGRAM ESP — Enter Serial Programming The following BASIC program can be used to demonstrate the serial communications capability of the Ambassador This command causes the counter to enter the serial pro- controls. The program requires the user to enter an Ambas- gramming mode.
  • Page 23 SERIAL PROGRAMMING READ (RPI) WRITE (WPI) READ (RPI) WRITE (WPI) PROGRAM PROGRAM C SCALER 00nnnnnn nnnnnn is a decimal number INPUT 1 DISABLED between 000001 and 999999. If INPUTS SCALERS ..nnnnnn=000000, then 1.00000 is loaded. BYP P1 OUT CTRL C DEC PT where d is between 0 and 5.
  • Page 24 SERIAL PROGRAMMING WRITE (WPI) READ (RPI) WRITE (WPI) READ (RPI) RST KEY DISABLED PROGRAM PROGRAM Enter 2 digit decimal ID #0-99. SER PORT OPTIONS RS C EDG SER PORT Program as 40nn where nn is between 00 and 99. The ID # RS C LVL will be converted to hexadecimal for transmission.
  • Page 25 TROUBLESHOOTING SELF-TEST ROUTINES If the counter shows ERROR 4, press the front panel reset key. This will reset all user programmable options The 5760X-401 counter has several built in self-test routines. to the factory default settings and re-run all tests. The counter performs these tests each time power is applied.
  • Page 26 TROUBLESHOOTING 3. Reset all program parameters to the factory de- IV. Other Problems faultsettings (enter the program mode and select the PROGRAM OPTIONS menu, select the USER Other problems are usually caused by programming and/or PROGRAM sub-menu, select the LOAD DEF PRO- wiring errors.
  • Page 27: Specifications

    SPECIFICATIONS POWER INPUT: COUNT INPUTS: AC Operation: 115 VAC (+/-15%) std., 50 to 60 Hz, 7 W Sink: Impedance: 4.6k ohms to +5 VDC 230 VAC (+/-15%) opt., 50 to 60 Hz, 7 W Voltage: high 3.5 to 34.0, low 0.0 DC Operation: 10 to 15 VDC opt., 300 mA maximum to 1.9 VDC...
  • Page 28: Parts And Accessories

    PARTS/ACCESSORIES Spare Parts 36172-202 Front Panel Gasket 48369-200 Mounting Clip 28748-200 Screw for Mounting Clip 48355-110 Terminal Strip - 10 Position 48355-112 Terminal Strip - 12 Position Ambassador Family Accessories 48183-401 Desk Mount Kit (enclosure for flat surface mounting) 58801-460 RS-485 to RS-232 Communications Converter 58801-461 RS-485 to RS-232 Communications Converter (Europe)
  • Page 29 Occupational Safety and Health Act of 1970, or any shipment to Buyer. This is a limited warranty limited to its terms. This regulations issued thereunder. In no event shall Eaton be liable for warranty is void if the product has been altered, misused, taken apart any loss, damages, fines, penalty or expense arising under said or otherwise abused.
  • Page 30 Durant 901 South 12th Street Printed in U.S.A. Watertown, WI 53094 920-261-4070 • 800-540-9242 • FAX 920-261-9097...

This manual is also suitable for:

Durant ambassador series57601-40157602-401