Upi Configuration - Gigabyte G293-S42 User Manual

Hpc server - 4th gen intel xeon scalable server - 2u dp 8-gpu nvme/sata/sas, hpc server - 4th gen intel xeon scalable server - 2u dp 4-gpu nvme/sata/sas, hpc server - 4th gen intel xeon scalable server - 2u dp 8-gpu nvme/sata/sas, hpc server - 4th gen int
Table of Contents

Advertisement

5-3-3 UPI Configuration

Parameter
UnCore General
Configuration
Description
Press [Enter] to configure advanced items.
Uncore Status
Š
– Press [Enter] to view the Uncore status.
Link Frequency Select
Š
– Selects the UPI link frequency.
– Options available: 9.6GT/s, 10.4GT/s, 11.2GT/s, Auto. Default setting
is Auto.
SNC (Sub NUMA)
Š
– Enable/Disable Sub NUMA Cluster function.
– Options available: Disable, Enable SNC2 (2-clusters). Default setting
is Disable.
Stale AtoS
Š
– Enable/Disable Stale A to S directory optimization.
– Options available: Disable, Enable, Auto. Default setting is Auto.
LLC dead line alloc
Š
– Enable/Disable fill dead lines in LLC.
– Options available: Disable, Enable, Auto. Default setting is Enable.