EAS822, EBS852, EBS862 ELECTRONIC UNIT | OI/EAS822/EBS852/EBS862-EN REV. D
... 6 Electrical connections
... Connection of the power and signal cable on the electronic unit
EBS862
1 Commissioning and service field
2 Ground terminal
3 Terminals (power supply)
4 Cable clamps (shielding)
5 Power supply cable
Figure 17: Terminal box
6 Motor cable
7 Terminals (motor)
8 Signal cable
9 Terminals (signals)
Connection of cable shielding
1 Cable clip
2 Cable sheath
Figure 18: Cable shielding
1. Remove the cover for the terminal compartment.
2. Cut the cable sheath to the required length.
3. Separate the cable shield and pull it back over the outer
sheath
4. Push the cable through the cable gland and fasten it with the
clamp.
5. Make sure that the cable shield is in contact with the clip and
the housing.
6. Connect the cable (see electrical connections starting on
page Electronic Unit EBN862 (Contrac)
on page 22).
7. Check the cable connections for tight fit and fasten the cable
gland.
8. Screw the cover of the connection chamber back on tight.
Note
When installing the cover for the connection area, take care not
to damage the sealing ring. If the sealing ring is damaged,
contact the manufacturer.
3 Shielding
4 Housing