Tektronix P6137 Instructions Manual

10x passive probe for 2400 series oscilloscopes

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading

Summary of Contents for Tektronix P6137

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 Instructions P6137 10X Passive Probe for 2400 Series Oscilloscopes 070-6432-03 www.tektronix.com 070643203...
  • Page 3 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077...
  • Page 4 Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located.
  • Page 6: General Safety Summary

    Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. P6137 10X Passive Probe Instructions...
  • Page 7 CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols on the Product. The following symbols may appear on the product: CAUTION Refer to Manual P6137 10X Passive Probe Instructions...
  • Page 8: Service Safety Summary

    Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. To avoid electric shock, do not touch exposed connections. P6137 10X Passive Probe Instructions...
  • Page 9 Service Safety Summary P6137 10X Passive Probe Instructions...
  • Page 10: Operating Considerations

    Operating Considerations This manual provides the information necessary to begin making measurements with your P6137 probe. Topics are presented in the following order: Operating Considerations—Information about using the probe. Specifications—Characteristics of the probe. Adjustment/Maintenance—Instructions for cleaning the probe and replacing major assemblies.
  • Page 11 Operating Considerations Figure 2: Typical response with a 6-inch ground lead (Tr = 2 ns) The Low-Inductance Lead (shown in Figure 3) provided with all P6137 probes allows for a substantial reduction of ground-lead inductance ( 32 nH instead of 140 nH).
  • Page 12: Specifications

    Specifications The P6137 is a compact, 1.5 meter 10X, passive voltage probe designed specifically for use with the Tektronix 2400 Series oscilloscopes. It is fully compatible with the Tektronix family of compact probe accessories. Table 1: Electrical Characteristics (Probe installed on 2400 Series...
  • Page 13 Net Weight 109 g (3.9 oz) Safety To avoid explosion, do not operate this product in an explosive atmosphere unless it has been specifically certified for such operation. This product meets the requirements of UL 1244. P6137 10X Passive Probe Instructions...
  • Page 14 Typical test equipment required includes a Tektronix PG506A pulse generator (rise time of 1 ns) & Tunnel Diode Pulser (Tektronix part number 067-0681-01) with pulse rise time of 125 ps. Use a 50 terminated BNC-to-compact probe tip adapter (such as Tektronix part number 013-0227-00) to connect the probe to the equipment.
  • Page 15 Accumulated dirt can be removed with a soft cloth dampened with a non-residue type cleaner, preferably isopropyl alcohol. Before using any other type of cleaner, consult your Tektronix Service Center or representative. In particular, avoid benzene, toluene, xylene, acetone, or similar solvents.
  • Page 16: Parts Replacement

    NOTE. Probe adjustment may be necessary after assembly replacement (refer to the adjustment procedures). The probe tip assembly, compensation box, and cable are available as separate units through your local Tektronix field Office or representative. Individual components within the compensation box are not replaceable. Compensation Box/Cable Disassembly and Replacement Use the following procedure to disassemble and replace the compensation box or the cable assembly (refer to Figure 8 for parts nomenclature).
  • Page 17 8. Press the new BNC shell onto the compensation box making sure the identification pin goes through the oval slot in the shell (see Figure 8). 9. Snap the plastic covers back in place. P6137 10X Passive Probe Instructions...
  • Page 18 PO BOX 500 TK1287 ENOCH MANUFACTURING COMPANY MS 94 PO BOX 5087 PORTLAND, OR 97208–5087 TK2548 XEROX CORPORATION 14181 SW MILLIKAN WAY BEAVERTON, OR 97005 TK2565 VISION PLASTICS INC 26000 SW PARKWAY CENTER DRIVE WILSONVILLE, OR 97070 P6137 10X Passive Probe Instructions...
  • Page 19 8908 COMP BOX ASSY:1.5 METER,P6137 80009 206–0389–00 206–0389–01 8909 COMP BOX ASSY:1.5M,P6137 80009 206–0389–01 220–0099–00 NUT,RETAINING:CABLE/COMP BOX TK1287 ORDER BY DESCRIPTION 205–0192–00 8908 SHELL,ELEC CONN:BNC,ACETAL,DOVE GRAY 80009 205–0192–00 205–0192–01 8909 SHELL,ELEC CONN:BNC,ACETAL,DOVE GRAY TK2565 205–0192–01 P6137 10X Passive Probe Instructions...
  • Page 20 CLIP,ELECTRICAL:ALLIGATOR,0.155 L,STL CS PL 80009 344–0398–00 013–0254–00 9307 ADAPTER, CONNEC:BNC TO PROBE TIP, MALE, 24931 28P–302–2 STRAIGHT, PROBE, 2.14 INCH L, INTERNAL 4.5 X 0.077 MM TH 131–5031–00 8926 CONNECTOR, PROB:PACKAGE OF 25, COMPACT 80009 131–5031–00 P6137 10X Passive Probe Instructions...
  • Page 21 Parts Replacement P6137 10X Passive Probe Instructions...

Table of Contents