Crown EL-25 Installation & Operation Manual page 7

Self generating steam jacketed kettles
Table of Contents

Advertisement

SELF GENERATING STEAM JACKETED KETTLES, MODELS EL AND EP
2.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect the electrical power supply and place a tag
at the disconnect switch to indicate that you are working on the
circuit.
ELECTRICAL CONNECTIONS
A Control Box with power supply equivalent to electrical rating of the kettle should be located
conveniently nearby.
Remove the wiring compartment cover and make electrical connections per wiring diagram
located inside the control housing cover panel. A waterproof electrical connection from power
supply to rear of control housing must be provided.
Kettle must be grounded in accordance with requirements of the National Electrical Code or
applicable local codes.
Ground kettle to terminal provided in control housing.
Once proper connections are made, replace wiring compartment cover, turn power ON and
check for proper operation.
SERVICE CONNECTIONS
All internal wiring for the kettle is complete.
If faucet is provided connect water supply and check for proper operation.
INSTALLATION CODES AND STANDARDS
Your electric kettle must be installed in accordance with:
1. Provincial and local codes, or in the absence of local codes, with: C.S.A. C22.1 Canadian
Electrical Code, Part 1, or in the U.S.A., the National Electrical Code ANSI/NFPA-70 (latest
edition).
2. ANSI NFPA Standard #96, "Vapor Removal from Cooking Equipment," (latest edition),
available from the National Fire Protection Association, Batterymarch Park, Quincy, MA,
USA, 02269.
Part No. 10068R6
INSTALLATION AND OPERATION MANUAL,
7
2018-06-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents