Crown EL-25 Installation & Operation Manual page 18

Self generating steam jacketed kettles
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL,
SELF GENERATING STEAM JACKETED KETTLES, MODELS EL AND EP
9.0 TROUBLESHOOTING (Continued)
9.2 EXTREMELY SLOW COOKING TIME
If the cooking time is abnormally slow, then the difficulty may be due to air being present in the
kettle jacket. To remove air, follow AIR VENTING INSTRUCTIONS.
If the kettle will not reach and maintain Pressure Gauge zone in the green area on the gauge
when cold, a slow leak may have developed in the jacket. Check all fitting connections to jacket
including the heating element gasket. Tighten or replace if necessary.
Slow cooking time may also be due to a burnt out heating element. Test elements and if
defective, replace complete element assembly.
9.3 KETTLE WILL NOT OPERATE WHEN TURNED ON
Check that power supply is available to kettle.
Kettle will not operate if water level is inadequate in jacket. Follow 9.1 LOW WATER LEVEL
instructions.
Also check for defective power switch or loose wire connections.
Initially, when Thermostat Knob is dialed and TEMPERATURE indicator light does not come on,
then it may be assumed that malfunction is due to either a defective Thermostat or loose wiring
connection(s). If TEMPERATURE indicator light comes on when Thermostat Knob is dialed
fully (i.e. setting of '10'), then eventually the kettle should read its maximum temperature
(290 F) in the jacket and a corresponding pressure reading of approximately 40 psi should be
evident on the Pressure Gauge (on kettles rated at 50 psi).
Finally, when the kettle is turned ON and Thermostat Knob dialed, check that the Contactors
are being energized and power is being made available to the heating elements. Replace
defective Contactors.
9.4 DRAW-OFF VALVE LEAKS
If leak occurs through the valve stem, replace the "O" ring. If the leak can be attributed to faulty
sealing occurring between the stem disc and valve seat, then this may be due to dried on food
residue. Clean the dried on food residue with an extremely fine emery cloth. If the rubber
vulcanized stem piece has been damaged it must be replaced.
Part No. 10068R6
18