Connection
5.2 Power supply
SCALANCE W774 M12 EEC
For the power supply, there are two options with the SCALANCE W774 M12 EEC:
● Direct feed in via the four-pin M12 socket (position
– Round cable cross-section with 6 to 8 mm diameter.
– Two-wire cable with 0.5 to 1.5 mm2 cross-section per wire.
– Permitted tensile load at least 100 N. - UL
– Listing of the cables according to the national installation regulations. In areas where
● Power over Ethernet via the M12 Ethernet interface P2 (position
interface P1 is not capable of PoE.
The four-pin M12 socket has the following pin assignment:
Pin
1
2
3
4
40
NEC or CEC applies: Type PTLC or ITC
P o E
L A N
P 2
L A N
P 1
3
M
4
M
L 2
2
L 1
1
4
1
3
2
Signal
L1+
L2+
M
M
Operating Instructions, 09/2017, C79000-G8976-C325-09
)
). The other Ethernet
Assignment
24 VDC
24 VDC
Ground
Ground