6-13. EHSC-TM9C.UK
Power supply
to Booster heater
3~ 230V 50Hz
L1
L2
L3
(1)
(3)
(5)
ECB1
2 4 6
1
3
5
A1
BHCP
2
4
6
A2
BHC1
BHC2
1
3
5
A1
1
3
5
A1
2
4
6
A2
2
4
6
A2
2
2
2
BH1
BH2
BHF
BHT
2
1
2
3
1
2
3
1
2
3
5
2
7
1. Symbols used in wiring diagram are,
: terminal block.
2. Indoor unit and outdoor unit connecting wires have polarities,
make sure to match terminal numbers (S1, S2, S3) for correct
wirings,
3. Since the outdoor unit side electric wiring may change, be sure to
check the outdoor unit electric wiring diagram for service.
Table 1 Signal Inputs
Name Terminal block Connector
IN1
TBI.1 13-14
Room thermostat 1 input
IN2
TBI.1 11-12
Flow switch 1 input
IN3
TBI.1 9-10
Flow switch 2 input (Zone1)
IN4
TBI.1 7-8
Demand control input
IN5
TBI.1 5-6
Outdoor thermostat input *1
IN6
TBI.1 3-4
Room thermostat 2 input
IN7
TBI.1 1-2
Flow switch 3 input (Zone2)
IN8
TBI.3 1-2
Electric energy meter 1
IN9
TBI.3 3-4
Electric energy meter 2
IN10
TBI.3 5-6
Heat meter
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be
reduced.
*2. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting" screen in
the service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating/cooling & DHW)
OUT2
TBO.1 3-4
Water circulation pump 2 output (Space heating/cooling for Zone1)
Water circulation pump 3 output (Space heating/cooling for Zone2) *1
OUT3
TBO.1 5-6
2-way valve 2b output *2
OUT4
TBO.2 4-6 CNV1 3-way valve (2-way valve) output
TBO.2 1-2
OUT5
Mixing valve output *1
TBO.2 2-3
OUT6
CNBH 1-3 Booster heater 1 output
OUT7
CNBH 5-7 Booster heater 2 output
OUT8
TBO.4 5-6
Cooling signal output
OUT9
TBO.4 3-4 CNIH Immersion heater output
OUT10 TBO.3 1-2
Boiler output
OUT11 TBO.3 3-4
Error output
OUT12 TBO.3 5-6
Defrost output
OUT13 TBO.4 1-2
2-way valve 2a output *2
OUT14
CNP4 Water circulation pump 4 output (DHW)
OUT15 TBO.3 7-8
Comp. ON signal
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
OCH571D
CNPWM
(WHT)
1
3
3
CNP1
(WHT)
TBO.1
1
X1
M
1
1~
2
MP1
3
M
X2
3
1~
M
2WV2b
1~
4
MP2
X3
5
M
6
1~
MP3
X14
1
M
1~
3
MP4
CNP4
(RED)
TBO.2
X5A
Close
1
M
N
Open
1~
2
X5B
3
MXV
X4
1
4
*1
5
5
6
CNV1
(WHT)
TBO.3
X10
1
Signal output
(Boiler)
2
X11
3
Signal output
(Error)
4
X12
Signal output
5
(Defrost)
6
X15
7
Signal output
(Comp ON)
8
TBO.4
X13
1
CNIH
M
(ORN)
CNBHT
2
X9
(BLK)
2WV2a
3
1
4
CNBC
3
X8
(GRY)
5
Signal output
(Cooling)
6
CNBH
(WHT)
1
3
CNBHT
(BLK)
CNBC
(GRY)
1
3
X6
1
3
X7
5
7
CNBH
(WHT)
: connector,
Item
OFF (Open)
Refer to SW2-1 in <6-16. DIP switch functions>.
Refer to SW2-2 in <6-16. DIP switch functions>.
Refer to SW3-2 in <6-16. DIP switch functions>.
Normal
Heat source OFF/ Boiler operation *2
Standard operation Heater operation/ Boiler operation *2
Refer to SW3-1 in <6-16. DIP switch functions>.
Refer to SW3-3 in <6-16. DIP switch functions>.
Refer to installation manual.
Item
1
<How to use TBO.1 to 4>
2
Connect them using either way as shown below.
4
F1
6
Tool
CN01
F2
(WHT)
Conductor
Outline view
Top view
1
TBO.1
2
3
1
CNP1
4
3
(WHT)
5
6
F2
6.3A 250V
1
TBO.2
1
CNP4
1
3
(RED)
2
3
SW5
4
5
8
LED1
6
1
1
CNV1
1
TBO.3
SW4
(WHT)
5
2
6
3
1
4
5
SW3
6
LED2
7
8
8
1
1
TBO.4
LED3
2
SW2
3
4
8
5
1
1
6
CNIH
3
(ORN)
SW1
1
1
CNBC
CNBHT
8
(GRY)
(BLK)
3
3
1
LED4
CNBH
(WHT)
7
CN1A
CNW5
CNW12
(WHT)
(WHT)
(RED)
1
1
1
2
4
4
2 4 6 8 10 12 14
2 4 6 8 10 12 14
2
4
6
1 3 5 7 9 11 13
1 3 5 7 9 11 13
1
3
5
TBI.2
TBI.1
TBI.3
TBI.1
1
2
3
4
5
6
7
8
9
1
2
1
4
1
3
1
2
t
°
t
°
t
°
t
°
t
°
Symbol
TB1
ECB1
MP1
MP2
MP3
MP4
ON (Short)
3WV(2WV1) 3-way valve (2-way valve 1)(Local supply)
2WV2a
2WV2b
MXV
BHT
BHF
BH1
BH2
BHC1
BHC2
BHCP
TH1
TH2
THW1
THW2
THW5
THW6
THW7
THW8
THW9
OFF
ON
THWB1
OFF
ON
THWB2
OFF
ON
IN1
IN2
OFF
ON
IN3
IN4
Heating
DHW
IN5
Close
IN6
Stop
IN7
Open
IN8
OFF
ON
IN9
OFF
ON
IN10
OFF
ON
FLOW TEMP. CONTROLLER (FTC5)
OFF
ON
TBO.1−4 Terminal block <Outputs>
TBI.1−3 Terminal block <Signal Inputs, Thermistor>
OFF
ON
F1
Normal
Error
F2
Normal Defrost
SW1−5 DIP switch *See <6-16. DIP switch functions>.
OFF
ON
X1−15
OFF
ON
LED1
LED2
OFF
ON
LED3
LED4
CNPWM Pump speed control signal for MP1
CN108
26
Indoor unit powered
Indoor unit powered
via outdoor unit
by independent source
To outdoor
Power supply
unit
~/N 230V 50Hz
Tool
L
N
S1
S2
S3
TB1
L
N
Conductor
BLK
1
BLK
BLK
2
CN01
BLK
(WHT)
4
1
6
1
CN01
2
2
CN01
(WHT)
4
(WHT)
4
F1
6
6
10A 250V
1
CN3C
BRN
(BLU)
1
1
3
CN3C
CN3C
ORN
(BLU)
(BLU)
3
3
1
CNPWM
(WHT)
3
CNRF
Wireless receiver
(WHT)
(Option)
CN105
WiFi adapter
(RED)
(Option)
CNIT
(BLU)
1
CN22
(BLU)
2
CN108
CN21
CN20
(YLW)
(RED)
*1
1
1
3WV
2WV1
2
3
4 5 6
4 5 6
TBO.2
TBO.2
8
10
12
M
M
7
9
11
13
1~
1~
3WV
2WV1
TBI.3
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
+
+
+
CN22
(BLU)
1
2
t
°
Name
Terminal block <Power supply, Outdoor unit>
Earth leakage circuit breaker for booster heater
Water circulation pump 1(Space heating/cooling & DHW)
Water circulation pump 2
(Space heating/cooling for Zone1)(Local supply)
Water circulation pump 3
(Space heating/cooling for Zone2)(Local supply)
Water circulation pump 4 (DHW)(Local supply)
2-way valve (For Zone1)(Local supply)
2-way valve (For Zone2)(Local supply)
Mixing valve (Local supply)
Thermostat for booster heater
Thermal fuse for booster heater
Booster heater 1
Booster heater 2
Contactor for booster heater 1
Contactor for booster heater 2
Contactor for booster heater protection
Thermistor (Room temp.)(Option)
Thermistor (Ref. liquid temp.)
Thermistor (Flow water temp.)
Thermistor (Return water temp.)
Thermistor (DHW tank water temp.)(Option)
Thermistor (Zone1 flow temp.)(Option)
Thermistor (Zone1 return temp.)(Option)
Thermistor (Zone2 flow temp.)(Option)
Thermistor (Zone2 return temp.)(Option)
Thermistor (Boiler flow temp.)(Option)
Thermistor (Boiler return temp.)(Option)
Room thermostat 1 (Local supply)
Flow switch 1 (Local supply)
Flow switch 2 (Local supply)
Demand control (Local supply)
Outdoor thermostat (Local supply)
Room thermostat 2 (Local supply)
Flow switch 3 (Local supply)
Electric energy meter 1 (Local supply)
Electric energy meter 2 (Local supply)
Heat meter (Local supply)
Fuse (T10AL250V)
Fuse (T6.3AL250V)
Relay
Power supply (FTC5)
Power supply (Main remote controller)
Communication (FTC5-Outdoor unit)
Reading or writing data to SD card
SD card connector
To outdoor
unit
S1
S2
S3
TB1
BRN
ORN
4
5
6
7
8
9
10
11
12
13
14
t
t
t
t
t
°
°
°
°
°